Uniflair LE

Perimeter cooling for medium and large data center environments

Explore Uniflair in 3D animation.
Leading edge precision cooling solutions specifically designed to maintain temperature and humidity within extremely tight tolerances. Perfect for racked and non-racked IT loads, these units meet the diverse requirements of any data center environment. When combined with hot or cold aisle containment solutions, the Uniflair LE products can further improve efficiency and achieve higher densities

Read More
Products Part Number
Product High Efficiency Chilled Water Units, Downflow, Backward Curved Fans and Electronic Commutated Motor Part Number HDCV
Product Direct Expansion Air-Cooled Units, Downflow with Backward Curved Fans Part Number TDAR
Product Direct Expansion Air-Cooled Unit, Downflow with Backward Curved Fans and Electronic Commutated Motor Part Number TDAV
Product Chilled Water Units, Downflow with Backward Curved Fans Part Number TDCR
Product Chilled Water Units, Downflow with Backward Curved Fans and Electronic Commutated Motor Part Number TDCV
Product Twin Cool Water-Cooled Units, Downflow with Backward Curved Fans Part Number TDDR
Product Twin Cool Water-Cooled Units, Downflow with Backward Curved fans and Electronic Commutated Motor Part Number TDDV
Product Energy Saving Units, Downflow with Backward Curved Fans Part Number TDER
Product Energy Saving Units, Downflow with Backward Curved Fans and Electronic Commutated Motor Part Number TDEV
Product Twin Cool Air-Cooled Units, Downflow with Backward Curved Fans Part Number TDTR
Product Twin Cool Air-Cooled Units, Downflow with Backward Curved Fans and Electronic Commutated Motor Part Number TDTV
Product Direct Expansion Water-Cooled Units, Downflow with Backward Curved Fans Part Number TDWR
Product Direct Expansion Water-Cooled Unit, Downflow, Backward Curved Fans and Electronic Commutated Motor Part Number TDWV
Product Direct Expansion Air-Cooled Units, Upflow with Backward Curved Fans Part Number TUAR
Product Direct Expansion Air-Cooled Unit, Upflow with Backward Curved Fans and Electronic Commutated Motor Part Number TUAV
Product Chilled Water Units, Upflow with Backward Curved Fans Part Number TUCR
Product Chilled Water Units, Upflow with Backward Curved Fans and Electronic Commutated Motor Part Number TUCV
Product Twin Cool Water-Cooled Units, Upflow with Backward Curved Fans Part Number TUDR
Product Twin Cool Water-Cooled Units, Upflow with Backward Curved Fans and Electronic Commutated Motor Part Number TUDV
Product Energy Saving Units, Upflow with Backward Curved Fans Part Number TUER
Product Energy Saving Units, Upflow with Backward Curved Fans and Electronic Commutated Motor Part Number TUEV
Product Twin Cool Air-Cooled Units, Upflow with Backward Curved Fans Part Number TUTR
Product Twin Cool Air-Cooled Units, Upflow with Backward Curved Fans and Electronic Commutated Motor Part Number TUTV
Product Direct Expansion Water-Cooled Units, Upflow with Backward Curved Fans Part Number TUWR
Product Direct Expansion Water-Cooled Units, Upflow, Backward Curved Fans and Electronic Commutated Motor Part Number TUWV
Energy Management
Automatic Floor Pressurization System Ensures stable airflow pressurization under floor regardless of changes made above the floor
Building Management Systems Units are designed to work with the most common BMS systems including BACnet and Modbus.
Local area network Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations
Network interface Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
Availability
Multi-functional Microprocessor Controller Allows the units to restart after a power failure without intervention; Allows for room level redundancy with up to ten units operating in a group; User friendly navigation with icon based displays to indicate mode of operation as well as room conditions; Allows for communication with multiple Building Management System protocols.
Redundant Components Single points of failure in the system have redundant compononents to maintain availability and reliability.
Electronic expansion valve Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring
Active response control Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
Direct drive motors Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
Serviceability
Easy service access Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Service monitoring All the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.
Operational Service Allows critical components to be maintained/replaced while the system is in operation.
Total Cost of Ownership
Tandem compressors Quiet and efficient operation of compressors, connected on a common refrigerant circuit for staged capacity control (not available for some models/configuration)
Economization Achieved by utilizing cool ambient air during winter months to take advantage of economizer hours and eliminating compressor operation.
Electronically Commutated Fans Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
Modular strategy Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expeditures and provides deferred investment throughout the life of the facility.
Optimized management Connection between the Computer Room Air Conditioners and the chillers guarantees energy efficiency, based on real instantaneous load conditions (optional)