InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14

InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Left
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Left
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Left
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Right
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Straight
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Back
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Left
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Right
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Straight
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Back
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
  • Close-coupled, chilled water cooling for medium to large data centers

View Product Overview

ACRC101 Features

Key Features

Rack Height
42U
Input Connections
IEC 60320 C14
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14
Close-coupled, chilled water cooling for medium to large data centers
  • Hot swappable fans
    Allows system to remain operational if a fan replacement is required.
  • Modular design
    Enables IT projects that were previously infeasible or cost-prohibitive.
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Rack inlet control
    Rack inlet control guarantees inlet temperature to IT equipment.
  • Top or Bottom Piping Connections
    The unit includes both top and bottom piping connections.

Uniflair Chilled Water InRow Cooling Features & Benefits

Availability

Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.

Agility

Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Scalable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Casters
Provides flexibility to move the unit to wherever cooling is required.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Manageability

Real-Time capacity monitoring
Real-time display of current and available cooling.
Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Total cost of Ownership

Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.

Product Distribution

United Arab Emirates, Afghanistan, Antigua and Barbuda, Anguilla, Albania, Armenia, Netherlands Antilles, Angola, Argentina, Austria, Australia, Aruba, Azerbaijan, Bosnia and Herzegovina, Barbados, Belgium, Burkina Faso, Bulgaria, Bahrain, Burundi, Benin, Bermuda, Bolivia, Brazil, Bahamas, Botswana, Belarus, Belize, Canada, The Democratic Republic Of Congo, Switzerland, Côte d'Ivoire, Chile, Cameroon, China, Colombia, Costa Rica, Cyprus, Czech Republic, Germany, Djibouti, Denmark, Dominica, Dominican Republic, Algeria, Ecuador, Estonia, Egypt, Eritrea, Spain, Ethiopia, Finland, Fiji, France, Gabon, United Kingdom, Grenada, Georgia, French Guiana, Ghana, Gambia, Guadeloupe, Greece, Guatemala, Guyana, Hong Kong, Honduras, Croatia, Haiti, Hungary, Indonesia, Ireland, Israel, India, Iraq, Iceland, Italy, Jamaica, Jordan, Japan, Kenya, Saint Kitts And Nevis, South Korea, Kuwait, Cayman Islands, Kazakhstan, Lebanon, Saint Lucia, Liberia, Lithuania, Luxembourg, Latvia, Morocco, Madagascar, Macedonia, Mali, Myanmar, Mongolia, Martinique, Mauritania, Malta, Mauritius, Malawi, Mexico, Malaysia, Mozambique, Namibia, Nigeria, Nicaragua, Netherlands, Norway, New Zealand, Oman, Panama, Peru, Philippines, Pakistan, Poland, Puerto Rico, Portugal, Paraguay, Reunion, Romania, Russia, Rwanda, Saudi Arabia, Sweden, Singapore, Slovenia, Slovakia, Sierra Leone, Senegal, Somalia, Suriname, El Salvador, Turks And Caicos Islands, Togo, Thailand, Tajikistan, Turkmenistan, Turkey, Trinidad and Tobago, Taiwan, Tanzania, Ukraine, Uganda, United States, Uruguay, Uzbekistan, Saint Vincent And The Grenadines, Venezuela, U.S. Virgin Islands, Vietnam, Yemen, Mayotte, South Africa, Zambia, Zimbabwe

Technical Specifications

Input

Input frequency
50/60 Hz
Number of Power Cords
2
Input Power
1380.0Watts

Communications & Management

Control panel
Multifunction LCD status and control console

Physical

Maximum Height
1991MM, 199.11CM
Maximum Width
300MM, 29.97CM
Maximum Depth
1069MM, 106.88CM
Net Weight
162.73KG
Shipping weight
193.41KG
Shipping Height
2118MM, 211.81CM
Shipping Width
746MM, 74.63CM
Shipping Depth
1137MM, 113.67CM
Color
Black
Units per Pallet
1.0

Environmental

Audible noise at 1 meter from surface of unit
79.0dBA

Conformance

Approvals
C-Tick, CE, CUL listed, EN 55022 class A, EN 55024, EN 60950, EN 61000-3-2, Eurovent, FCC part 15 class A, GS Mark, ICES-003, IEC 60950, IEC 61000-3-2, IEC 61000-3-3, Industry Canada, UL listed, VCCI, VDE
Standard warranty
1 year (parts only)

General

Air Flow
1368.65lps
Minimum Water Inlet Temperature
7.0 °C

Options

Services