Galaxy PW 120 Kva

Share:

Galaxy PW 120 Kva

GWTUPS120

Description: 3 phase UPS power protection designed to meet the unique requirements of small to large facility and equipment room applications.

Includes : User Manual

Galaxy PW 120 Kva
Discontinued

MGE Galaxy Features & Benefits

  • Parallel-capacity capable
    Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
  • Parallel-redundant capable
    Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
  • LCD display
    Alpha-Numeric Display which displays system parameters and alarms.
  • Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Manual maintenance bypass
    Reduces installation costs by eliminating the need for an external mechanical bypass.
  • Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Frequency and voltage regulation
    Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Front-access servicing
    Simplifies installation and UPS maintenance while minimizing space requirements.
  • LCD graphics display
    Text and mimic diagrams that display modes of operation, system parameters and alarms.
  • Network manageable
    Provides remote power management of the UPS over the network.
  • Audible alarms
    Provides notification of changing utility power and UPS power conditions
  • LED status indicators
    Quickly understand unit and power status with visual indicators.
  • Generator compatible
    Ensures clean, uninterrupted power to protected equipment when generator power is used.
  • Automatic internal bypass
    Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Product Distribution
Product Distribution

Andorra , United Arab Emirates , Antigua and Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Argentina , Austria , Aruba , Azerbaijan , Bosnia and Herzegovina , Barbados , Belgium , Bulgaria , Bahrain , Bermuda , Bolivia , Brazil , Bahamas , Belarus , Belize , Canada , Switzerland , Chile , Colombia , Costa Rica , Serbia and Montenegro , Cuba , Cyprus , Czech Republic , Germany , Denmark , Dominica , Dominican Republic , Ecuador , Estonia , Spain , Finland , Falkland Islands , France , United Kingdom , Grenada , Georgia , French Guiana , Guadeloupe , Greece , Guatemala , Guyana , Honduras , Croatia , Haiti , Hungary , Ireland , Israel , Iraq , Iran , Iceland , Italy , Jamaica , Jordan , Saint Kitts And Nevis , Kuwait , Cayman Islands , Kazakhstan , Lebanon , Saint Lucia , Liechtenstein , Lithuania , Luxembourg , Latvia , Moldova , Madagascar , Macedonia , Mongolia , Martinique , Malta , Mauritius , Mexico , Nicaragua , Netherlands , Norway , Oman , Panama , Peru , Pakistan , Poland , Puerto Rico , Portugal , Paraguay , Reunion , Romania , Russia , Saudi Arabia , Sweden , Slovenia , Slovakia , El Salvador , Turks And Caicos Islands , Tajikistan , Turkmenistan , Turkey , Trinidad and Tobago , Ukraine , United States , Uruguay , Uzbekistan , Saint Vincent And The Grenadines , Venezuela , U.S. Virgin Islands , Yemen , Mayotte

Print Technical Specification

Output

  • Output power capacity
    96.0 KWatts / 120.0 kVA
  • Max Configurable Power (Watts)
    96.0 KWatts / 120.0 kVA
  • Nominal Output Voltage
    400V 3PH

Input

  • Nominal Input Voltage
    400V 3PH

Physical

  • Maximum Height
    1900mm , 190.0CM
  • Maximum Width
    1220mm , 122.0CM
  • Maximum Depth
    838mm , 83.8CM
  • Net Weight
    905.0KG
  • Shipping weight
    905.0KG
  • Shipping Height
    1900mm , 190.0CM
  • Shipping Width
    1220mm , 122.0CM
  • Shipping Depth
    838mm , 83.8CM
Manuals and Warranties
Title
Size
Updated On
PDF

Size

1096KB

Updated On

2018-06-18

Schneider Electric Important Safety Instructions in English, Chinese Simplified, French, German, European Spanish, Italian, Russian, Portuguese Brazilian, Dutch, Japanese and Korean
PDF

Size

552KB

Updated On

2018-06-15

MGE Galaxy PW Battery Circuit breaker kits Installation Manual
PDF

Size

241KB

Updated On

2018-06-14

MGE Galaxy PW Battery and Auxiliary Cubicles Supplied Empty Installation Manual
PDF

Size

919KB

Updated On

2018-06-12

MGE Galaxy PW, MGE Galaxy 5000, MGE Galaxy 6000 and MGE Galaxy 7000 Synchronization Module Installation and User Manual
PDF

Size

987KB

Updated On

2018-06-07

MGE Galaxy PW User Manual
Agency Approvals
Title
Size
Updated On
PDF

Size

41KB

Updated On

2017-02-17

U.L Approval for MGE EPS 6000/7000/8000 - MGE Galaxy 5000 - MGE Galaxy PW - MGE STS Epsilon
Title
Size
Updated On
MGE Galaxy PW, One-Line Diagrams
MGE Galaxy PW, Mechanical
CAD Source File
2080KB
2017-02-13

BIM Models, UPS, MGE Galaxy PW