APC Silcon 160kW 400V UPS

SL160KH

Description: 3 phase UPS power protection with industry leading efficiency and robust performance for data centers and facilities

Includes : Installation Guide , Parallel Card , Relay Board , Triple Chassis for 3 SmartSlots , User Manual , Web/SNMP Management Card

APC Silcon 160kW 400V UPS
Discontinued

Silcon Features & Benefits

  • 200% overload capability
    The APC Silcon Series has the ability to supply 200% overload in normal operation for a period of 60 seconds. This enables the system to handle inrush currents, sudden peak loads and output faults without transitioning to bypass. The result is increased availability.
  • Automatic internal bypass
    Supplies utility power to the connected loads in the event of a UPS power overload or fault.
  • Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Generator compatible
    Ensures clean, uninterrupted power to protected equipment when generator power is used.
  • Parallel-redundant capable
    Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
  • Parallel-capacity capable
    Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
  • Fully-rated power kVA equals kW
    Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
  • Temperature-compensated battery charging
    Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Locking cabinet
    Prevents unauthorized access to the UPS.
  • Manageable external batteries
    Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
  • Audible alarms
    Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
  • SmartSlot
    Customize UPS capabilities with management cards.
  • LCD display
    Alpha-Numeric Display which displays system parameters and alarms.
  • Network manageable
    Provides remote power management of the UPS over the network.
  • Manageable external batteries
    Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
  • Parallel-capacity capable
    Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
  • Parallel-redundant capable
    Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
  • Input power factor correction
    Eliminates the need for an external phase-compensation unit and minimizes installation costs by enabling the use of smaller generators and cabling.
  • Fully-rated power kVA equals kW
    Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
  • Network manageable
    Provides remote power management of the UPS over the network.
  • Generator compatible
    Ensures clean, uninterrupted power to protected equipment when generator power is used.
Product Distribution
Product Distribution

Andorra , Afghanistan , Antigua and Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Austria , Australia , Aruba , Azerbaijan , Bosnia and Herzegovina , Barbados , Bangladesh , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Brunei , Bolivia , Brazil , Bhutan , Botswana , Belarus , Belize , The Democratic Republic Of Congo , Central African Republic , Congo , Switzerland , Côte d'Ivoire , Cook Islands , Chile , Cameroon , China , Colombia , Costa Rica , Serbia and Montenegro , Cuba , Cyprus , Czech Republic , Germany , Djibouti , Denmark , Dominican Republic , Algeria , Ecuador , Estonia , Egypt , Western Sahara , Eritrea , Spain , Ethiopia , Finland , Fiji , Falkland Islands , France , Gabon , United Kingdom , Georgia , Ghana , Gibraltar , Gambia , Guinea , Equatorial Guinea , Greece , Guatemala , Guyana , Hong Kong , Honduras , Croatia , Hungary , Indonesia , Ireland , Israel , India , Iraq , Iran , Iceland , Italy , Jamaica , Jordan , Kenya , Cambodia , South Korea , Kuwait , Cayman Islands , Kazakhstan , Lebanon , Liechtenstein , Sri Lanka , Liberia , Lesotho , Lithuania , Luxembourg , Latvia , Morocco , Moldova , Macedonia , Mali , Myanmar , Mongolia , Mauritania , Malta , Mexico , Malaysia , Mozambique , Namibia , Niger , Nigeria , Nicaragua , Netherlands , Norway , Nepal , New Zealand , Oman , Panama , Peru , Papua New Guinea , Philippines , Pakistan , Poland , Puerto Rico , Portugal , Paraguay , Romania , Russia , Rwanda , Sudan , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , El Salvador , Chad , Togo , Thailand , Tajikistan , Turkmenistan , TP , Turkey , Trinidad and Tobago , Tanzania , Ukraine , Uganda , Uruguay , Uzbekistan , Venezuela , U.S. Virgin Islands , Vietnam , XF , Yemen , South Africa , Zambia , Zimbabwe

Print Technical Specification

Output

  • Output power capacity
    160.0 KWatts / 160.0 kVA
  • Max Configurable Power (Watts)
    160.0 KWatts / 160.0 kVA
  • Nominal Output Voltage
    230V , 400V 3PH
  • Output Voltage Note
    Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
  • Efficiency at Full Load
    96.0 %
  • Output Voltage Distortion
    Less than 3%
  • Output Frequency (sync to mains)
    50 Hz, 60 Hz
  • Output Frequency (not synced)
    60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
  • Load Crest Factor
    Unlimited
  • Topology
    Delta Conversion On-Line
  • Waveform type
    Sine wave
  • Bypass
    Built-in Static Bypass

Input

  • Nominal Input Voltage
    400V 3PH
  • Input frequency
    50 Hz - programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8%, 60 Hz - programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8%
  • Input Connections
    Hard Wire 5-wire (3PH + N + G), Hard Wire 4-wire (3PH + PEN), Hard Wire 4-wire (3PH + N)
  • Input voltage range for main operations
    323 - 437 (380V), 340 - 460 (400V), 353 - 477 (415V)V
  • Input voltage adjustable range for mains operation
    323 - 437 (380 V), 340 - 460 (400V), 357 - 477 (415 V)V
  • Number of Power Cords
    1
  • Efficiency at Full Load
    96.0 %
  • Input Power Factor at Full Load
    0.99

Batteries & Runtime

  • Battery type
    No internal battery - uses external battery system
  • Extendable Run Time
    1

Communications & Management

  • Interface Port(s)
    Contact Closure , DB-25 RS-232
  • Control panel
    Multi-function LCD status and control console
  • Audible Alarm
    Beep for each 52 alarm conditions
  • Emergency Power Off (EPO)
    Yes
  • Available SmartSlot™ Interface Quantity
    2

Physical

  • Maximum Height
    1800mm , 180.0CM
  • Maximum Width
    1125mm , 112.5CM
  • Maximum Depth
    800mm , 80.0CM
  • Net Weight
    811.82KG
  • Shipping weight
    833.64KG
  • Shipping Height
    2050mm , 205.0CM
  • Shipping Width
    1350mm , 135.0CM
  • Shipping Depth
    1100mm , 110.0CM
  • Color
    Dark green (NCS 7020 B50G) , Light grey (NCS 2703-G84Y)
  • Units per Pallet
    1.0

Environmental

  • Operating Temperature
    0 - 40 °C
  • Operating Relative Humidity
    0 - 95 %
  • Operating Elevation
    0-999.9meters
  • Storage Temperature
    -50 - 40 °C
  • Storage Relative Humidity
    0 - 95 %
  • Storage Elevation
    0-15000meters
  • Audible noise at 1 meter from surface of unit
    66.0dBA
  • Online thermal dissipation
    21154.0BTU/hr
  • Protection Class
    IP 30 with IP 31 optional

Conformance

  • Approvals
    C-tick, CE, EN 50091-1, EN 50091-2, ISO 9001, ISO 14001, TUV
  • Equipment protection policy
    --
  • Standard warranty
    1 year repair or replace, optional on-site warranties available, optional extended warranties available
Manuals and Warranties
Title
Size
Updated On
PDF

Size

4465KB

Updated On

2018-06-15

This is the Installation Guide for the APC Silcon Series 120 through 160kW 400V
PDF

Size

250KB

Updated On

2018-06-15

Instructions for operating APC's Out-of-Band Management Card with the APC Silcon Series UPS. For installation instructions
PDF

Size

1923KB

Updated On

2018-06-15

This is the User Guide for the APC Silcon Series 120 through 160kW 480V
PDF

Size

987KB

Updated On

2018-06-14

Product information and installation instructions for AP9604S and AP9604SR, for use with the APC Silcon Series UPSs.
PDF

Size

1303KB

Updated On

2018-06-14

Installation and Quick Configuration Instructions for the Triple Chassis for the APC Silcon Series UPSs (AP9604S and AP9604SR).
PDF

Size

987KB

Updated On

2018-06-11

Product information and installation instructions for AP9604S and AP9604SR
PDF

Size

987KB

Updated On

2018-05-24

This is the User Guide for the APC Silcon Series 120 through 160kW 400V
Title
Size
Updated On
Silcon, UPS with External Battery, 160kW, UPS Single Feed, 5 Module N+1 (640kW), UPS Package
CAD Source File
107KB
2018-06-12

CAD Source File
78KB
2018-06-15

CAD Source File
358KB
2018-06-11

Silcon, UPS with External Battery, 160kW, UPS Single Feed, 4 Module N+1 (480kW), UPS Package
CAD Source File
93KB
2018-06-15

CAD Source File
78KB
2018-06-14

CAD Source File
352KB
2018-06-19

Silcon, UPS with External Battery, 160kW, UPS Single Feed, 4 Module Capacity (640kW), UPS Package
CAD Source File
93KB
2018-06-08

CAD Source File
81KB
2018-06-15

CAD Source File
354KB
2018-06-19

Silcon, UPS with External Battery, 160kW, UPS Single Feed, 3 Module N+1 (320kW), UPS Package
CAD Source File
80KB
2018-06-13

CAD Source File
79KB
2018-06-12

CAD Source File
347KB
2018-06-15

Silcon, UPS with External Battery, 160kW, UPS Single Feed, 3 Module Capacity (480kW), UPS Package
CAD Source File
80KB
2018-06-05

CAD Source File
79KB
2018-06-06

CAD Source File
347KB
2018-06-19

Silcon, UPS with External Battery, 160kW, UPS Single Feed, 2 Module N+1 (160kW), UPS Package
CAD Source File
74KB
2018-06-15

CAD Source File
63KB
2018-06-13

CAD Source File
341KB
2018-06-18

Silcon, UPS with External Battery, 160kW, UPS Single Feed, 2 Module Capacity (320kW), UPS Package
CAD Source File
67KB
2018-06-18

CAD Source File
63KB
2018-06-19

CAD Source File
337KB
2018-06-15

Silcon, UPS with External Battery, 160kW, UPS Single Feed, 1 Module Capacity (160kW), UPS Package
CAD Source File
53KB
2018-05-24

CAD Source File
47KB
2018-06-19

CAD Source File
327KB
2018-06-14

CAD Source File
469KB
2018-06-13

CAD Source File
226KB
2018-06-05

Silcon, UPS with External Batteries, 160kW, Single Feed, 5 Module N+1 (640kW), UPS package
CAD Source File
372KB
2018-06-15

CAD Source File
73KB
2018-06-12

Silcon, UPS with External Batteries, 160kW, Single Feed, 4 Module N+1 (480kW), UPS package
CAD Source File
368KB
2018-06-11

CAD Source File
66KB
2018-06-18

CAD Source File
79KB
2018-06-15

Silcon, UPS with External Batteries, 160kW, Single Feed, 4 Module Capacity (640kW), UPS package
CAD Source File
368KB
2018-06-12

CAD Source File
67KB
2018-06-12

CAD Source File
79KB
2018-06-15

Silcon, UPS with External Batteries, 160kW, Single Feed, 3 Module N+1 (320kW), UPS package
CAD Source File
366KB
2018-06-15

CAD Source File
60KB
2018-06-13

CAD Source File
78KB
2018-06-12

Silcon, UPS with External Batteries, 160kW, Single Feed, 3 Module Capacity (480kW), UPS package
CAD Source File
60KB
2018-06-12

CAD Source File
78KB
2018-06-15

Silcon, UPS with External Batteries, 160kW, Single Feed, 2 Module N+1 (160kW), UPS package
CAD Source File
361KB
2018-06-12

CAD Source File
52KB
2018-06-15

Silcon, UPS with External Batteries, 160kW, Single Feed, 2 Module Capacity (320kW), UPS package
CAD Source File
361KB
2018-06-13

CAD Source File
52KB
2018-06-12

CAD Source File
77KB
2018-06-14

Silcon, UPS with External Batteries, 160kW, Single Feed, 1 Module Capacity (160kW), UPS package
CAD Source File
480KB
2018-06-19

CAD Source File
265KB
2018-06-12

CAD Source File
352KB
2018-06-11

CAD Source File
48KB
2018-06-12

CAD Source File
56KB
2018-06-12

Silcon, 415V, UPS with External Batteries, 160kW, Single Feed, 5 Module N+1 (640kW)
CAD Source File
449KB
2018-06-11

CAD Source File
79KB
2018-06-14

CAD Source File
125KB
2018-06-13

CAD Source File
92KB
2018-06-15

Silcon, 415V, UPS with External Batteries, 160kW, Single Feed, 4 Module N+1 (480kW)
CAD Source File
446KB
2018-06-15

CAD Source File
71KB
2018-06-12

CAD Source File
127KB
2018-06-12

CAD Source File
91KB
2018-06-15

Silcon, 415V, UPS with External Batteries, 160kW, Single Feed, 4 Module Capacity (640kW)
CAD Source File
446KB
2018-06-12

CAD Source File
71KB
2018-06-12

CAD Source File
127KB
2018-06-14

Silcon, 415V, UPS with External Batteries, 160kW, Single Feed, 3 Module N+1 (320kW)
CAD Source File
424KB
2018-06-12

CAD Source File
68KB
2018-06-13

CAD Source File
86KB
2018-06-14

Silcon, 415V, UPS with External Batteries, 160kW, Single Feed, 3 Module Capacity (480kW)
CAD Source File
64KB
2018-06-12

CAD Source File
78KB
2018-06-12

CAD Source File
86KB
2018-06-14

Silcon, 415V, UPS with External Batteries, 160kW, Single Feed, 2 Module N+1 (160kW)
CAD Source File
413KB
2018-06-19

CAD Source File
56KB
2018-06-15

CAD Source File
79KB
2018-06-14

CAD Source File
73KB
2018-06-12

Silcon, 415V, UPS with External Batteries, 160kW, Single Feed, 2 Module Capacity (320kW)
CAD Source File
413KB
2018-06-12

CAD Source File
56KB
2018-06-12

CAD Source File
79KB
2018-06-14

CAD Source File
73KB
2018-06-13

Silcon, 415V, UPS with External Batteries, 160kW, Single Feed, 1 Module Capacity (160kW)
CAD Source File
521KB
2018-06-18

CAD Source File
294KB
2018-06-13

CAD Source File
394KB
2018-06-14

CAD Source File
48KB
2018-06-14

CAD Source File
60KB
2018-06-14

CAD Source File
54KB
2018-06-19

Firmware Upgrades

Firmware Upgrades
Part Number
Updated On

Part Number

SFDP3E326A

Updated On

2004-01-17

Part Number

SFDP3E372

Updated On

2010-02-04
InfraStruxure Manager
Part Number
Updated On

Part Number

AP9430

Updated On

2018-09-05

Part Number

AP9431

Updated On

2018-09-05

Category

Sub-Category


APC Silcon 160kW 400V Spare Part Kit Level 1

This parts kit contains spare parts applicable to the APC product model shown

APC Silcon 160kW 400V Spare Part Kit Level 2

This parts kit contains spare parts applicable to the APC product model shown

InfraStruXure Manager, 25 Node License Only

Management platform that increases visibility of server rooms and small datacenters by outlining the health and status of all APC devices.

Emergency Power Off (EPO)

Provides a single point of emergency equipment shutdown for up to eight APC InfraStruXure® devices and one third-party device

APC Silcon 160kW 400V Spare Part Kit Level 3

This parts kit contains spare parts applicable to the APC product model shown

(1) Additional Contract Preventive Maintenance Visit 5X8 for (1) Silcon 120 to 160kVA

Performed at any point for your UPS or cooling system lifecycle, regardless of your service contract status. On-demand services include part replacement services for batteries, parts, reactive time and materials (T&M), etc.

Scheduling Upgrade to 7X24 for Existing Assembly Service for 151 to 500 kVA

A set of service options designed to deliver the vital resources, expertise, and tools needed to quickly and efficiently implement your APC by Schneider Electric solution

APC Silcon 160kW 400V Spare Part Kit Level 4

This parts kit contains spare parts applicable to the APC product model shown

1 Year of Remote Monitoring Service for (25) Nodes

A 7x24 monitoring service that acts as a primary or secondary support function. Trained technicians will monitor the health status of the physical infrastructure to help diagnose, notify and resolve problems before they become critical.

InfraStruXure Manager, 100 Node License Only

Management platform that increases visibility of server rooms and small datacenters by outlining the health and status of all APC devices.


Show results per page

Related Products, Accessories & Services

View all accessories and replacement batteries for this product