APC Service Bypass Panel- 100-240V; 30A; BBM; Hardwire Input/Output

Share:

APC Service Bypass Panel- 100-240V; 30A; BBM; Hardwire Input/Output

SBP3000

Description: Extremely reliable service bypass panels designed for APC InfraStruXure® Type A, Smart-UPS, and Symmetra UPS products.

Includes : Installation Guide , Rack Mounting Brackets , User Manual

APC Service Bypass Panel- 100-240V; 30A; BBM; Hardwire Input/Output

Includes: Installation Guide , Rack Mounting Brackets , User Manual

SBP3000 Features

APC Service Bypass Panel- 100-240V; 30A; BBM; Hardwire Input/Output

  • Wall mountable
    Ideal for Network Closets and Server Rooms.
  • Wrap Around System Bypass
    (3) Breaker maintenance bypass panel to isolate the UPS from the critical load

Maintenance Bypass Panels Features & Benefits

Product Distribution
Product Distribution

Andorra , United Arab Emirates , Antigua and Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Austria , Aruba , Azerbaijan , Bosnia and Herzegovina , Barbados , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Bermuda , Bolivia , Brazil , Bahamas , Botswana , Belarus , Belize , Canada , The Democratic Republic Of Congo , Central African Republic , Congo , Switzerland , Côte d'Ivoire , Chile , Cameroon , Colombia , Costa Rica , Serbia and Montenegro , Cuba , Cyprus , Czech Republic , Germany , Djibouti , Denmark , Dominica , Dominican Republic , Algeria , Ecuador , Estonia , Egypt , Western Sahara , Eritrea , Spain , Ethiopia , Finland , Falkland Islands , France , Gabon , United Kingdom , Grenada , Georgia , French Guiana , Ghana , Gibraltar , Gambia , Guinea , Guadeloupe , Equatorial Guinea , Greece , Guatemala , Guyana , Honduras , Croatia , Haiti , Hungary , Ireland , Israel , Iraq , Iran , Iceland , Italy , Jamaica , Jordan , Kenya , Saint Kitts And Nevis , Kuwait , Cayman Islands , Kazakhstan , Lebanon , Saint Lucia , Liechtenstein , Liberia , Lesotho , Lithuania , Luxembourg , Latvia , Morocco , Moldova , Madagascar , Macedonia , Mali , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mexico , Mozambique , Namibia , Niger , Nigeria , Nicaragua , Netherlands , Norway , Oman , Panama , Peru , Pakistan , Poland , Puerto Rico , Portugal , Paraguay , Reunion , Romania , Russia , Rwanda , Saudi Arabia , Sudan , Sweden , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , El Salvador , Turks And Caicos Islands , Chad , Togo , Tajikistan , Turkmenistan , Tunisia , Turkey , Trinidad and Tobago , Tanzania , Ukraine , Uganda , United States , Uruguay , Uzbekistan , Saint Vincent And The Grenadines , Venezuela , U.S. Virgin Islands , XF , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Output

  • Nominal Output Voltage
    100V , 120V , 230V
  • Other Output Voltages
    110
  • Overload Protection
    Yes
  • Maximum Total Current Draw
    30
  • Output Connections
    (1) Hard Wire 3-wire (H N + G) (Battery Backup)

Input

  • Nominal Input Voltage
    100V , 120V , 230V
  • Input frequency
    50/60 Hz
  • Input Connections
    Hard Wire 3 wire (1PH+N+G)
  • Load Power Factor Range
    0 to 1
  • Maximum Input Current
    30A
  • Maximum Line Current
    30A

Physical

  • Maximum Height
    89mm , 8.9CM
  • Maximum Width
    432mm , 43.2CM
  • Maximum Depth
    635mm , 63.5CM
  • Rack Height
    2U
  • Net Weight
    12.0KG
  • Shipping weight
    22.0KG
  • Shipping Height
    203mm , 20.3CM
  • Shipping Width
    610mm , 61.0CM
  • Shipping Depth
    991mm , 99.1CM
  • Color
    Black

Environmental

  • Operating Temperature
    -20 - 50 °C
  • Operating Relative Humidity
    0 - 95 %
  • Operating Elevation
    0-4500meters
  • Storage Temperature
    -40 - 65 °C
  • Storage Relative Humidity
    0 - 95 %
  • Storage Elevation
    0-15000meters

Conformance

  • Approvals
    CSA, EN 60950, GOST, IEC 60950, UL 1778, VDE
  • Standard warranty
    2 years (parts only)
Manuals and Warranties
Title
Size
Updated On
PDF

Size

541KB

Updated On

2018-06-13

Installation Guide for Service Bypass Panels 3/5/6/10/16 KVA
Title
Size
Updated On