Our Brands

Std Exch APC Silcon 10kW 400V UPS With 3 Battery Drawers

SL10KHB01Q

notification_critical
information_stroke
  • What does the end of standard service mean ?

    End of standard service is the last date APC will be able to provide you maintenance services (repair, spare parts, etc.).

  • Need more help

    Contact Customer Care Center - available 24 a day.

SL10KHB01Q has not been replaced. Please contact your customer care centre for more information.
arrow2_down

Specifications

Overview
Lead timeWhile Supplies Last
Main
Main Input Voltage400 V 3 phases
Main Output Voltage230 V
400 V 3 phases
rated power in W10000 W
rated power in VA10000 VA
output connector typeHard wire 4-wire (3P + E) 1
Hard wire 5-wire (3P + N + E) 1
Hard wire 3-wire (3P) 1
Hard wire 4-wire (3P + N) 1
Hard wire 4-wire (3P + PEN) 1
number of rack unit0U
number of cables1
General
Number of power module10000
Number of power module free slots0
Number of power module filled slots0
redundantNo
Physical
colourDark green (NCS 7020-B50G)
Light grey (NCS 2703-G84Y)
height140 cm
width100 cm
depth80 cm
net weight306.82 kg
mounting locationFront
mounting preferenceNo preference
mounting modeNot rack-mountable
USB compatibleNo
Input
network frequency50 Hz programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8 %
60 Hz programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8 %
number of input connectors1 hard wire 5-wire (3P + N + E)
1 hard wire 4-wire (3P + PEN)
1 hard wire 4-wire (3P + N)
input voltage limits323...437 V adjustable 380 V
340...460 V adjustable 400 V
357...477 V adjustable 415 V
323...437 V 380 V
340...460 V 400 V
353...477 V 415 V
Input Power Factor at Full Load0.99
Output
Maximum configurable power in W10000 W
output frequency50 Hz sync to mains
60 Hz sync to mains
60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised
50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
crest factorUnlimited
UPS typeDelta conversion on-line
Wave typeSine wave
Maximum configurable power in VA10000 VA
Conformance
product certificationsC-Tick
CE
TÜV
standardsEN 50091-1
EN 50091-2
ISO 9001
ISO 14001
Environmental
ambient air temperature for operation0…40 °C
relative humidity0…95 %
operating altitude0...3333 ft
ambient air temperature for storage-50…40 °C
storage Relative Humidity0…95 %
storage altitude0.00…15240.00 m
acoustic level52 dBA
heat dissipation1842 Btu/h
IP degree of protectionIP30
IP31 optional
Batteries & Runtime
number of battery filled slots0
number of battery free slots0
additional informationConfigurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Battery power in VAH0 VAh runtime
extended runtime1
Communications & Management
free slots2
preinstalled deviceNetwork management card
control panelMultifunction LCD status and control console
alarmBeep for each 52 alarm conditions
Emergency power offYes
Packing Units
Package 1 Weight328.64 kg
Package 1 Height160 cm
Package 1 width110 cm
Package 1 Length90 cm
Number of Units in Package 31
Contractual warranty