Presentation | Effective three phase power protection against downtime and data loss for mission critical applications. Ruggedized version including dust filter and conformance coated boards for harsh environments. Includes UPS and external battery cabinet for customized runtime. |
---|---|
Lead time | Usually Ships within 2 Weeks |
Main Input Voltage | 400 V 3 phases |
---|---|
Other Input Voltage | 380 V 415 V |
Main Output Voltage | 400 V 3 phases |
Rated power in W | 54000 W |
Rated power in VA | 60000 VA |
Output connector type | Hard wire 5-wire (3P + N + E) 1 |
Battery type | Lead-acid battery |
Provided equipment | CD with software Dust filter Installation guide Network management card User manual |
Bypass wiring configuration | 5 wire (3P + N + E) |
---|---|
Number of power module free slots | 0 |
Number of power module filled slots | 0 |
Redundant | No |
Height | 190 cm |
---|---|
Width | 141.2 cm |
Depth | 95 cm |
Net weight | 1415 kg |
Mounting preference | No preference |
USB compatible | No |
Network frequency | 45...65 Hz |
---|---|
Number of input connectors | 1 hard wire 5-wire (3P + N + E) |
Input voltage limits | 323...437 V adjustable 380 V 340...460 V adjustable 400 V 357...477 V adjustable 415 V 340...477 V |
Maximum input current | 228 A |
Switching current capacity | 160 A |
Max short time withstand current | 16 kA |
Input harmonic distortion | Less than 5 % for full load |
Input protection type | 3-pole circuit breaker |
Inrush current | 200 A peak |
Input Power Factor at Full Load | 0.09 |
Maximum configurable power in W | 54000 W |
---|---|
Harmonic distortion | Less than 5 % |
Output frequency | 50/60 Hz +/- 5 % sync to mains |
Crest factor | 3 : 1 |
Output voltage tolerance | +/- 2% static and 100% load step |
Output overload operation | 10 minutes at 125% and 30 seconds at 150% |
Neutral output current | 87 A |
Maximum configurable power in VA | 60000 VA |
Product certifications | CE EAC |
---|---|
Standards | EN/IEC 62040-1-1 EN/IEC 62040-2 EN/IEC 62040-3 ISTA 2B |
Ambient air temperature for operation | 0…40 °C |
---|---|
Relative humidity | 0…95 % |
Operating altitude | 0...3000 ft |
Ambient air temperature for storage | -20…45 °C |
Storage Relative Humidity | 0…95 % |
Storage altitude | 0.00…4572.00 m |
Acoustic level | 65 dBA |
IP degree of protection | IP20 |
Efficiency | View Efficiency Graph |
---|---|
Number of battery filled slots | 0 |
Number of battery free slots | 0 |
Additional information | KW/kVA = 0.9 PF with ambient temp up to 25°C. kW/kVA = 0.8 PF with ambient temp above 25°C |
Battery voltage | +/- 192 V (split battery referenced to neutral) |
Battery power in VAH | 0 VAh runtime |
Battery life | 3…5 year(s) |
Extended runtime | 0 |
Preinstalled device | Network management card |
---|---|
control panel | Multifunction LCD status and control console |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 197.8 cm |
Package 1 Width | 112 cm |
Package 1 Length | 164.9 cm |
Package 1 Weight | 1435 kg |
Warranty | 1 year on-site repair or replace with factory authorized Start-Up |
---|
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance.
Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn moreResource performance
Energy efficient product
Take-back program available
Well-being performance
Mercury free
RoHS exemption information
EU RoHS Directive
Compliant
Environmental Disclosure
Circularity Profile
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.
G3HT60KHB4S is replaced by: