APC Back-UPS 1100VA, 230V, AVR, Universal and IEC Sockets
BX1100LI-MS
Discontinued on:24 August 2022
To be end-of-service on:30 April 2023
Recommended replacement(s)
Replacement battery (1) is available
Environmental performance of the product Learn more
Sustainable by Design
Specifications
Lead time | Usually in Stock |
---|
Run time for load WEnter the total load (power draw) of all devices that will be protected by the UPS. This will be used to estimate the run time of your devices during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down. Min-max: 55-550 W | |
---|---|
Max. Capacity Used The maximum percentage of UPS capacity used to support your specified load. | |
Main Input Voltage | 230 V |
Rated power in W | 550 W |
Rated power in VA | 1100 VA |
output connection type | 2 IEC 60320 C13 4 universal receptacle |
Cable length | 1.22 m |
Number of cables | 1 |
Battery type | Lead-acid battery |
Provided equipment | user manual warranty card |
---|---|
product web sub-family | Entry level |
Number of power module free slots | 0 |
Number of power module filled slots | 0 |
Redundant | No |
Colour | Black |
---|---|
Height | 21.5 cm |
Width | 13 cm |
Depth | 33.6 cm |
Net weight | 9.2 kg |
Mounting preference | No preference |
Mounting mode | Not rack-mountable |
Two post mountable | 0 |
USB compatible | No |
Network frequency | 50/60 Hz +/- 3 Hz auto-sensing |
---|---|
Input voltage limits | 150...280 V |
Maximum input current | 10 A |
Switching current capacity | 10 A |
Input protection type | 3-pole circuit breaker |
Input current | 10 A (1 phase) |
Input Power Factor at Full Load | 0.5 |
Maximum configurable power in W | 550 W |
---|---|
Output frequency | 50/60 Hz +/- 1 Hz sync to mains 50/60 Hz +/- 1 Hz unsynchronised |
UPS type | Line interactive |
Wave type | Stepped approximation to a sinewave |
Maximum configurable power in VA | 1100 VA |
Transfer time | 4 ms typical : 6 ms maximum |
Product certifications | CE |
---|
Ambient air temperature for operation | 0…40 °C |
---|---|
Relative humidity | 0…95 % |
Operating altitude | 0...10000 ft |
Ambient air temperature for storage | -15…40 °C |
Storage Relative Humidity | 0…95 % |
Storage altitude | 0.00…9144.00 m |
Acoustic level | 45 dBA |
Run Time | View Runtime Graph |
---|---|
Efficiency | View Efficiency Graph |
Number of battery filled slots | 1 |
Number of battery free slots | 0 |
Battery recharge time | 6 h |
Battery charger power | 16 W rated |
Battery power in VAH | 96 VAh runtime |
Battery life | 2…4 year(s) |
Replacement battery | RBC17 |
Extended runtime | 0 |
Control panel | LED status display with load and battery bar-graphs and on line : on battery : replace battery : and overload indicators |
---|---|
Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge energy rate | 273 J |
---|
Unit Type of Package 1 | Db |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 29.5 cm |
Package 1 Width | 44 cm |
Package 1 Length | 24.5 cm |
Package 1 Weight | 10.6 kg |
SCC14 | 10731304315169 |
Warranty | 2 years repair or replace |
---|
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance.
Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn more
Resource performance
Energy efficient product
Take-back program available
Well-being performance
Mercury free
Certifications & Standards
REACh Regulation
EU RoHS Directive
Environmental Disclosure
Circularity Profile
Documents
Software and Firmware
Need more information? Check our technical FAQs!