Galaxy VM 160 kVA UPS Parallel 400-400 V with Backfeed protection, Start up 5x8
GVMPB160KHS
Specifications
Presentation | Highly compact, energy efficient 3-phase UPS for data center, facility and industrial applications. to be used with external battery cabinets. Please click here for additional runtime information. |
---|---|
Lead time | Usually Ships within 2 Weeks |
Main Input Voltage | 400 V 3 phases |
---|---|
Other Input Voltage | 380 V 415 V |
Main Output Voltage | 400 V 3 phases |
Other Output Voltage | 380 V 415 V |
Rated power in W | 144 kW |
Rated power in VA | 160 kVA |
Output connector type | Hard wire 4-wire (3P + E) 1 Hard wire 5-wire (3P + N + E) 1 |
Battery type | External battery system |
Provided equipment | Built-in modbus protocol adapter Dust filter Installation guide Integrated network management Seismic compliance Top and bottom cable entry |
Bypass voltage tolerance | +/- 10 % settable from +/- 4/6/8 and 10 % |
---|---|
Max bypass input current | 231 A |
Bypass current protection | 400 A |
Redundant | No |
Colour | White |
---|---|
Height | 197 cm |
Width | 105.2 cm |
Depth | 85.4 cm |
Net weight | 699 kg |
USB compatible | No |
Network frequency | 40...70 Hz |
---|---|
Number of input connectors | 1 hard wire 3-wire (3P + E) |
Input voltage limits | 250...600 V adjustable 320...456 V 380 V 320...480 V 400 V 320...498 V 415 V |
Maximum input current | 262 A |
Switching current capacity | 400 A |
Max short time withstand current | 65 kA |
Input harmonic distortion | Less than 3 % for full load |
Input protection type | GL fuse |
Inrush current | 200 A peak |
Load power factor | 0.5 leading to 0.5 lagging |
Input Power Factor at Full Load | 1 |
Maximum configurable power in W | 144 kW |
---|---|
Harmonic distortion | Less than 2 % |
Output frequency | 50/60 Hz +/- 1 Hz sync to mains 50/60 Hz +/- 1 Hz unsynchronised |
Crest factor | Unlimited |
Wave type | Sine wave |
Output voltage tolerance | +/- 1% static and +/- 3% at 100% load step |
Output harmonic distortion | < 2% linear load and < 3% non-linear load |
Output overload operation | 10 minutes at 125% and 60 seconds at 150% |
Required output current protection | 400 A |
Neutral output current | 231 A |
Bypass type | Built-in static bypass |
Maximum configurable power in VA | 160 kVA |
Product certifications | C-Tick CE ETL RCM |
---|---|
Standards | EN/IEC 62040-1 EN/IEC 62040-2 EN/IEC 62040-3 IBC 2012 and CBC2013 to Sds=2.02g OSHPD UL 1778 VFI-SS-111 |
Ambient air temperature for operation | 0…40 °C |
---|---|
Relative humidity | 0…95 % |
Operating altitude | 0...3333 ft |
Ambient air temperature for storage | -25…55 °C |
Storage Relative Humidity | 0…95 % |
Storage altitude | 0.00…14999.82 m |
Acoustic level | 65 dBA |
Heat dissipation | 19650 Btu/h |
IP degree of protection | IP20 |
Efficiency | View Efficiency Graph |
---|---|
Number of battery filled slots | 0 |
Number of battery free slots | 0 |
Battery voltage | 480 V |
Discharge battery voltage | 384 V |
Max current discharge | 314 A |
Battery power in VAH | 0 VAh runtime |
Extended runtime | 0 |
Free slots | 2 |
---|---|
Control panel | 7" touch screen display |
Emergency power off | Yes |
Unit Type of Package 1 | Db |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 215.6 cm |
Package 1 Width | 106 cm |
Package 1 Length | 149 cm |
Package 1 Weight | 744.5 kg |
Warranty | 1 year on-site repair or replace with factory authorized Start-Up |
---|
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance.
Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn moreResource performance
Energy efficient product
Take-back program available
Well-being performance
Mercury free
RoHS exemption information
EU RoHS Directive
Compliant
Environmental Disclosure
Circularity Profile
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.