APC Symmetra 8kVA Scalable to 8kVA N+1 220-240V
SY8KI
Discontinued on:31 December 2004
End-of-service on:31 December 2015
Recommended replacement(s)
Replacement battery (1) is available
Compatible Software
Specifications
Lead time | Usually in Stock |
---|
Run time for load WEnter the total load (power draw) of all devices that will be protected by the UPS. This will be used to estimate the run time of your devices during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down. Min-max: 560-5600 W | |
---|---|
Max. Capacity Used The maximum percentage of UPS capacity used to support your specified load. | |
Main Input Voltage | 230 V |
Other Input Voltage | 220 V 240 V |
Main Output Voltage | 230 V |
Other Output Voltage | 220 V 240 V |
Rated power in W | 5600 W |
Rated power in VA | 8000 VA |
output connection type | 8 IEC 60320 C13 |
Output connector type | Hard wire 3-wire (H N + E) 1 |
Number of rack unit | 0U |
Battery type | Lead-acid battery |
Provided equipment | CD with software User manual |
Number of power module | 3 |
---|---|
Number preinstalled power module | 2 |
Number of power module free slots | 0 |
Number of power module filled slots | 0 |
Redundant | Yes |
Colour | Beige |
---|---|
Height | 78.7 cm |
Width | 61 cm |
Depth | 69 cm |
Net weight | 167 kg |
Mounting location | Front |
Mounting preference | No preference |
Mounting mode | Not rack-mountable |
USB compatible | No |
Network frequency | 45...65 Hz auto-sensing |
---|---|
Number of input connectors | 1 hard wire 3-wire (1P + N + E) |
Input voltage limits | 155...276 V |
Input Power Factor at Full Load | 0.98 |
Maximum configurable power in W | 5600 W |
---|---|
Harmonic distortion | Less than 5 % at full load |
Output frequency | 47...53 Hz for 50 Hz nominal sync to mains 57...63 Hz for 60 Hz nominal sync to mains 60 Hz unsynchronised 50 Hz unsynchronised |
Crest factor | Up to 5 : 1 |
UPS type | Double conversion online |
Wave type | Sine wave |
Bypass type | Internal bypass (automatic and manual) |
Efficiency | 91 % (full load) |
Maximum configurable power in VA | 8000 VA |
Product certifications | C-Tick CE VDE |
---|---|
Standards | EN 50091-2 |
Ambient air temperature for operation | 0…40 °C |
---|---|
Relative humidity | 0…95 % |
Operating altitude | 0...10000 ft |
Ambient air temperature for storage | -15…45 °C |
Storage Relative Humidity | 0…95 % |
Storage altitude | 0.00…15240.00 m |
Acoustic level | 62 dBA |
Heat dissipation | 1720 Btu/h |
Run Time | View Runtime Graph |
---|---|
Number of battery filled slots | 2 |
Number of battery free slots | 0 |
Battery recharge time | 2.5 h |
Additional information | Configurable for 220 : 230 or 240 nominal output voltage |
Battery charger power | 688 W rated |
Battery power in VAH | 1728 VAh runtime |
Battery life | 3…5 year(s) |
Replacement battery | SYBATT |
Battery option | SYXR2B4I 1 3456 VAh SYXR4B4I 1 5184 VAh SYXR8B12I 1 8640 VAh SYXR12B12I 1 12096 VAh SYXR8B12I 2 15552 VAh SYXR12B12I 2 22464 VAh SYXR12B12I 3 32832 VAh SYXR12B12I 4 43200 VAh |
Extended runtime | 1 |
Free slots | 3 |
---|---|
Preinstalled device | Network management card |
Control panel | Multifunction LCD status and control console |
Alarm | Alarm when on battery : distinctive low battery alarm : configurable delays |
Emergency power off | Yes |
Unit Type of Package 1 | Db |
---|---|
Number of Units in Package 1 | 1 |
Warranty | 2 years repair or replace, optional on-site warranties available, optional extended warranties available |
---|
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.
SY8KI is replaced by: