APC Back-UPS Pro 500VA, 230V
BP500I
Discontinued on:10 June 2022
Recommended replacement(s)
Replacement battery (1) is available
+ Lifecycle Services
Specifications
Lead time | Usually in Stock |
---|
Run time for load WEnter the total load (power draw) of all devices that will be protected by the UPS. This will be used to estimate the run time of your devices during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down. Min-max: 30-300 W | |
---|---|
Max. Capacity Used The maximum percentage of UPS capacity used to support your specified load. | |
Main Input Voltage | 230 V |
Rated power in W | 300 W |
Rated power in VA | 500 VA |
output connection type | 3 IEC 60320 C13 1 IEC 60320 C13 surge 1 IEC Jumpers |
Number of rack unit | 0U |
number of cables | 1 |
Battery type | Lead-acid battery |
provided equipment | user manual |
---|---|
Number of power module free slots | 0 |
Number of power module filled slots | 0 |
Redundant | No |
colour | Beige |
---|---|
Height | 15.2 cm |
Width | 8.9 cm |
Depth | 35.6 cm |
Net weight | 7 kg |
Mounting location | Front |
Mounting preference | No preference |
Mounting mode | Not rack-mountable |
Two post mountable | 0 |
USB compatible | No |
network frequency | 50/60 Hz +/- 5 Hz auto-sensing |
---|---|
input voltage limits | 160...280 V |
Maximum configurable power in W | 300 W |
---|---|
UPS type | Line interactive |
Maximum configurable power in VA | 500 VA |
Transfer time | 2 ms typical |
Product certifications | C-Tick CE GOST VDE |
---|
Ambient air temperature for operation | 0…40 °C |
---|---|
relative humidity | 0…95 % |
Operating altitude | 0...10000 ft |
Ambient air temperature for storage | -15…45 °C |
storage Relative Humidity | 0…95 % |
Storage altitude | 0.00…15240.00 m |
Acoustic level | 45 dBA |
Heat dissipation | 50 Btu/h |
Run Time | View Runtime Graph |
---|---|
Number of battery filled slots | 0 |
Number of battery free slots | 0 |
Battery recharge time | 7 h |
Number of battery replacement quantity | 1 |
battery charger power | 13 W rated |
Battery power in VAH | 93 VAh runtime |
Battery life | 3…5 year(s) |
Replacement battery | RBC2 |
Extended runtime | 0 |
Free slots | 0 |
---|---|
Control panel | LED status display with on line : on battery : replace battery and overload indicators |
control panel | LED status display with on line : on battery : replace battery and overload indicators |
Noise suppression | Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 |
---|
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 22.9 cm |
Package 1 Width | 17.8 cm |
Package 1 Length | 48.3 cm |
Package 1 Weight | 8.163 kg |
SCC14 | 10731304017797 |
Warranty | 2 years repair or replace |
---|
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.
BP500I is replaced by: