Browse FAQs



APC Schneider Cooling Unit Identification
FM Air/Water ... Capacity KW FM 35 (10t ... w /Multicool W = Water Cooled w /Multicool w /Economizer G = Glycol Cooled w /Multicool w /Economizer BA ... W = Hot Water FM -CW Capacity KW FM 40 (12T ... Capacity KW Capacity KW FM 40 (12T ... Capacity KW W = Water Cooled G = Glycol Cooled ... Capacity KW 27 (8T ... W = Water Cooled G = Glycol Cooled AFX 1 = 1 Bay ... Bay 06 ( 1 Bay) 08 ( 1 Bay) W = Water Cooled
Network Air FM unit spare parts list
ADAPTER ROTO 1 1 /4" ... ADAPTER ROTO 1 "-14R ... ... ASSEMBLY FLOW RATER FM 35 RELSD SKU 0 M-3899 ... ASSEMBLY FLOW RATER FM 40 RELSD SKU 0 M-3900 ... ASSEMBLY FLOW RATER FM 50 RELSD SKU 0 M-3901 0 M-74763 0 M-74791A ... -RATER FM35 W / CAPILA UNRELEASED 0 M-6897 ... -RATER fm40 W / CAP LI ... 0 M-6898 ... -RATER fm50 W / CAP LI ... 0 M-6899 0 M-74480 ... FLOW RATER BRASS FM SERIE RELSD ITEM
How to navigate through an Network Air FM unit display
... an Network Air FM unit display. ... to your APC NetworkAIR FM DX Precision Air ... ... point setpoint is 27 °C ( ... ... .See the NetworkAIR FM DX 60 Hz ... work as a single System. ... Half capacity uses one compressor and half ... ... A setting of zero indicates that the ... ... are using the FM in a high ... ... compressor (stage 1 ) in a ... See the NetworkAIR FM DX 60 Hz ... ... supported by the NetworkAIR FM DX. event to one of the output ... Provide a unique name for each ... ... an input in one of the following ...
ACSC1XX Spare Parts List
1 0 M-61250 1 1 1 0 J-0w3163a ... 0 J-0w2818a ... 1 ... -230/ 1 /60 ( ... ... -240/ 1 /50 ( ... ... -230/ 1 /60, ... 1 ... -240/ 1 /50 SC ... 1 ... PUMP DUAL ASSY W /HOSES ( ... 0 N-0993se 0 J-0011 1 0 M-61169 1 1 0 M-61152 ( 0 M-61250 ... 1 1 ... ASSY - 17 KW IR 1 ... WASHABLE IR SERIES 1 /2" ... FITTING 1 /8" ...
EcoBreeze Variable Speed Drive Technical Spec’s
Motor power kW 15 kW ... 200 V , 1 kA ... Power dissipation in W 628 W at nominal load Speed range 1 ... ... ... AWG 14 L 1 , L2 ... , V, W , ... /+, PC /- terminal ... ... Prospective line Isc 1 kA ... .m L 1 , L2 ... , V, W , PA, ... /+, PC /- ... AI1 configurable voltage 0 ... ... ... AI3 configurable current 0 ... ... ... AOC configurable current 0 ... ... AOV configurable voltage 0 ... ...
What are the operational conditions for an InRoom (Stulz) Unit
... ), and 27 °C ( ... Frequency:60 Hz +/- 1 % ... Fluid inlet temperature ( G ): 30°C (86°F) Fluid outlet temperature ( G ): 40°C (104°F) Chilled water medium (CW): 0 % Glycol ... Downflow units with an external static pressure: 20 Pa (0.08 in w g ) Upflow units with an external static pressure: 50 Pa (0.20 in w g )
ACRP1XX, ACRD5XX, ACRP5XX, and ACRC5XX Parts List
... 0521 ADPTR ELBOW 1 /2 INCH ... ) 0 M-61194 ADPTR STRAIGHT 1 /2 INCH - 1 /2 INCH ... ... 0991 ADPTR STRAIGHT 1 /2 INCH ... ... CABLE ATS # 1 200-240v ... CABLE ATS # 1 480v 0w3122 CABLE ... ) 0 N-0933 ... ... LOOSE KIT] 0 J-0w99952 ... - SPARE PART 0 J-0w3163a ... ... DOUBLE SNAP CRIP 27 -31MM [ ... ... DOUBLE SNAP CRIP 27 -31MM 875 ... ... HEATER ASSY # 1 w0m-9895 ELBOW ADPTR REDUCTION 1 /2 INCH ... ... (Standard) 0 J-875 ...
What is the VFD RS485 Communication Error on my NetworkAIR FM/ir40?
... Error on my NetworkAIR FM /ir40? Network Air FM The FM controller continuously polls ... the VFDs, one data point at ... ... incremented if the FM controller receives either ... ... error on any one piece of data ... ... a value of zero . One possibility is that SW2, located under the RJ45 connector on the VFD, needs to be in the ON position. It is also possible that one or both VFDs have the wrong address programmed into them. ... The leftmost VFD should have a value of 1 and the other should have a value of 2.
Rack PDU 2G (AP8XXX) Network Port Sharing Information
... ability to share one IP address via one network connection) ... PDUs using only one ... a number, 1 to 4, ... ... are connected to one another in a ... ... reference part number 0 J-0w05545a ... ... " port of one of the grouped ... ... desired order, 1 to 4. ... ... have Display ID 1 . ... 2: 40 W ... access to outlets 1 , 2, ... 3 on unit 1 , ... 2, outlets 1 through 6 ... , and outlets 1 ,2, ...
Why won't my FM Humidifier Come On?
FM Humidifier not turning on ... FM ... FM Humidifier Not Coming On ... FM 35 – 50 KW ... Actual 0 % ... 1 . Check to see if the LEDs are on the humidifier board. 2. Check voltage at P73- 1 , with 100% demand there should be 24 volts there.


Results 1 - 10 of 50

Can't find what you are looking for?

Reach out to our customer care team to receive information on technical support, assistance for complaints and more.