Main
Main Input Voltage400 V 3 phases
Other Input Voltage380 V
415 V
Main Output Voltage400 V 3 phases
Other Output Voltage380 V
415 V
Rated power in W32000 W
Rated power in VA40000 VA
Output connector typeHard wire 5-wire (3P + N + E) 1
Battery typeLead-acid battery
Provided equipmentUser manual
General
product web sub-familyGalaxy 300
Number of power module free slots0
Number of power module filled slots0
RedundantNo
Physical
Height130 cm
Width50 cm
Depth86 cm
Net weight200 kg
Mounting preferenceNo preference
USB compatibleNo
Input
Network frequency45...65 Hz
Number of input connectors1 hard wire 5-wire (3P + N + E)
Input voltage limits340...460 V adjustable 400 V
340...460 V 400 V
Maximum input current60 A
Switching current capacity125 A
Input harmonic distortionLess than 9 % for full load
Input protection typeGL fuse
Inrush current200 A peak
Load power factor0.5 leading to 0.5 lagging
Input Power Factor at Full Load0.97
Output
Maximum configurable power in W32000 W
Harmonic distortionLess than 3 %
Output frequency50/60 Hz +/- 5 % sync to mains
50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
Crest factor2.5 : 1
Wave typeSine wave
Output voltage tolerance+/- 2% static and 100% load step
Output harmonic distortion< 3% linear load and < 5% non-linear load
Output overload operation60 seconds at 120% and 30 seconds at 145%
Required output current protection125 A
Bypass typeBuilt-in maintenance bypass
Maximum configurable power in VA40000 VA
Conformance
Product certificationsCE
TÜV
StandardsEN/IEC 62040-1-1
EN/IEC 62040-2
EN/IEC 62040-3
EN 61000-4-5
IEC 62040-2
Environmental
Ambient air temperature for operation0…35 °C
Relative humidity0…95 %
Operating altitude0...10000 ft
Ambient air temperature for storage-10…60 °C
Storage Relative Humidity0…95 %
Storage altitude0.00…9144.00 m
Acoustic level54.5 dBA
Heat dissipation2479 Btu/h
IP degree of protectionIP20
Batteries & Runtime
EfficiencyView Efficiency Graphaction_new_window
Number of battery filled slots0
Number of battery free slots0
Additional informationConfigurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Battery power in VAH0 VAh runtime
Extended runtime0
Communications & Management
Free slots0
Preinstalled deviceNetwork management card
Control panelMultifunction LCD status and control console
Emergency power offYes
Contractual warranty