APC Back-UPS 600VA, 230V without auto shutdown software, 3 India outlets
BX600C-IN
Replacement battery (1) is available
Description
This product is part of the Back-UPS range. This 600VA UPS has 3 outlets that provide UPS power backup and surge protection. It features a built-in AVR and is compatible with low power loads (e.g. Wi-Fi router, DSL modem). Its runtime at 100 Watts is 16 minutes. Its dimensions are 21.8 x 10.7 x 23.7 cm and 4.7 kg. APC Back-UPS is an ideal power backup and protection for home offices, desktop PCs, home entertainment systems, wifi-routers, and electronic devices.
Specifications
Lead time | Usually in Stock |
---|
Run time for load WEnter the total load (power draw) of all devices that will be protected by the UPS. This will be used to estimate the run time of your devices during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down. Min-max: 36-360 W | |
---|---|
Max. Capacity Used The maximum percentage of UPS capacity used to support your specified load. | |
Main Input Voltage | 230 V |
Rated power in W | 360 W |
Rated power in VA | 600 VA |
output connection type | 3 India 3-pin 6A |
Cable length | 1.22 m |
Number of cables | 1 |
Battery type | Lead-acid battery |
Provided equipment | user manual |
---|---|
Number of power module free slots | 0 |
Number of power module filled slots | 0 |
Redundant | No |
Colour | Black |
---|---|
Height | 21.8 cm |
Width | 10.7 cm |
Depth | 23.7 cm |
Net weight | 4.7 kg |
Mounting preference | No preference |
Mounting mode | Not rack-mountable |
Two post mountable | 0 |
USB compatible | No |
Network frequency | 45...65 Hz auto-sensing |
---|---|
plug standard | India 3-pin 6A |
Input voltage limits | 145...290 V |
Maximum configurable power in W | 360 W |
---|---|
Output frequency | 50 Hz sync to mains |
UPS type | Line interactive |
Wave type | Stepped approximation to a sinewave |
Full load runtime | 360 W |
Maximum configurable power in VA | 600 VA |
Transfer time | 10 ms typical : 12 ms maximum |
Product certifications | BIS |
---|
Ambient air temperature for operation | 0…40 °C |
---|---|
Relative humidity | 0…95 % |
Operating altitude | 0...3000 m |
Ambient air temperature for storage | -15…45 °C |
Storage Relative Humidity | 0…95 % |
Storage altitude | 0…15000 m |
Acoustic level | 45 dBA |
Run Time | View Runtime Graph |
---|---|
Number of battery filled slots | 0 |
Number of battery free slots | 0 |
Battery recharge time | 6 h |
Number of battery replacement quantity | 1 |
Battery voltage | 12 V |
Battery power in VAH | 53 VAh runtime |
Battery graph comments | Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output. |
Extended runtime | 0 |
Replacement battery | RBC2 |
Control panel | LED status display with on line : on battery : replace battery and building wiring fault |
---|---|
Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge energy rate | 255 J |
---|
Unit Type of Package 1 | Db |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 29.5 cm |
Package 1 Width | 31 cm |
Package 1 Length | 16.5 cm |
Package 1 Weight | 5.2 kg |
Warranty | 2 years repair or replace |
---|
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance.
Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn moreResource performance
Energy efficient product
Take-back program available
REACh Regulation
EU RoHS Directive
Not compliant
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.