APC Silcon 120kW 400V UPS w/ Backfeed Protection Contactor w/ RAL Color 2003
SL120KH-BPCX214
Discontinued on:31 December 2010
End-of-service on:31 December 2018
SL120KH-BPCX214 has not been replaced. Please contact your customer care centre for more information.
Compatible Software
Specifications
Lead time | Usually Ships within 4 Weeks |
---|
Main Input Voltage | 400 V 3 phases |
---|---|
Main Output Voltage | 230 V 400 V 3 phases |
Other Output Voltage | 380 V 415 V |
Rated power in W | 120000 W |
Rated power in VA | 120000 VA |
number of cables | 1 |
Battery type | External battery system |
provided equipment | Installation guide Parallel card Relay board Triple chassis for 3 SmartSlots User manual Web/SNMP management card |
Number of power module free slots | 0 |
---|---|
Number of power module filled slots | 0 |
Redundant | No |
colour | Orange |
---|---|
Height | 180 cm |
Width | 112.5 cm |
Depth | 80 cm |
Net weight | 800 kg |
Mounting location | Front |
Mounting preference | No preference |
Mounting mode | Not rack-mountable |
USB compatible | No |
network frequency | 50 Hz programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8 % 60 Hz programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8 % |
---|---|
number of input connectors | 1 hard wire 5-wire (3P + N + E) 1 hard wire 4-wire (3P + PEN) 1 hard wire 4-wire (3P + N) |
input voltage limits | 323...437 V adjustable 380 V 340...460 V adjustable 400 V 357...477 V adjustable 415 V 323...437 V 380 V 340...460 V 400 V 353...477 V 415 V |
Input Power Factor at Full Load | 0.99 |
Maximum configurable power in W | 120000 W |
---|---|
Harmonic distortion | Less than 3 % |
output frequency | 50 Hz sync to mains 60 Hz sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised |
Crest factor | Unlimited |
UPS type | Delta conversion on-line |
Wave type | Sine wave |
Bypass type | Built-in static bypass |
efficiency | 96 % (full load) |
Maximum configurable power in VA | 120000 VA |
product certifications | C-Tick CE TÜV |
---|---|
Standards | EN 50091-1 EN 50091-2 ISO 14001 ISO 9001 |
Ambient air temperature for operation | 0…40 °C |
---|---|
relative humidity | 0…95 % |
Operating altitude | 0...3333 ft |
Ambient air temperature for storage | -50…40 °C |
storage Relative Humidity | 0…95 % |
Storage altitude | 0.00…15240.00 m |
Acoustic level | 66 dBA |
Heat dissipation | 18084 Btu/h |
IP degree of protection | IP30 IP31 optional |
Number of battery filled slots | 0 |
---|---|
Number of battery free slots | 0 |
Additional information | Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage |
Battery power in VAH | 0 VAh runtime |
Extended runtime | 0 |
Free slots | 2 |
---|---|
control panel | Multifunction LCD status and control console |
Alarm | Beep for each 52 alarm conditions |
Emergency power off | Yes |
Warranty | 1 year repair or replace |
---|
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.