Specifications
Lead time | Special Order - Call for Quoted Lead Times |
---|
Main Input Voltage | 400 V 3 phases |
---|---|
Other Input Voltage | 380 V 415 V |
Main Output Voltage | 230 V 400 V 3 phases |
Other Output Voltage | 380 V 415 V |
Rated power in W | 8000 W |
Rated power in VA | 10000 VA |
output connector type | Hard wire 4-wire (3P + E) 1 Hard wire 5-wire (3P + N + E) 1 |
connections - terminals | 1 screw terminals |
Battery type | External battery system |
provided equipment | Bolt down brackets CD with software Network management card Power modules ship installed User manual Installation guide |
Bypass wiring configuration | 5 wire (3P + N + E) |
---|---|
Bypass voltage tolerance | +/- 10 % settable from +/- 4/6/8 and 10 % |
Number of power module free slots | 0 |
Number of power module filled slots | 0 |
Redundant | No |
colour | Black |
---|---|
Height | 82.3 cm |
Width | 35.2 cm |
Depth | 83.8 cm |
Net weight | 134 kg |
Mounting location | Front |
Mounting preference | No preference |
Mounting mode | Not rack-mountable |
USB compatible | No |
network frequency | 47...70 Hz auto-sensing |
---|---|
number of input connectors | 1 hard wire 5-wire (3P + N + E) |
input voltage limits | 304...477 V |
Maximum input current | 14 A |
Switching current capacity | 20 A |
Max short time withstand current | 30 kA |
Input harmonic distortion | Less than 5 % for full load |
Input protection type | 3-pole circuit breaker |
Load power factor | 0.5 leading to 0.5 lagging |
Input Power Factor at Full Load | 0.98 |
Maximum configurable power in W | 8000 W |
---|---|
Harmonic distortion | Less than 5 % at full load |
output frequency | 47...53 Hz for 50 Hz nominal sync to mains 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised |
Crest factor | Unlimited |
UPS type | Double conversion online |
Wave type | Sine wave |
Output harmonic distortion | < 2% for 0 to 100% linear load and < 5% for full non-linear load |
Output overload operation | 10 minutes at 125% and 30 seconds at 150% |
Bypass type | Built-in maintenance bypass Built-in static bypass |
Maximum output current | 16 A |
Maximum configurable power in VA | 10000 VA |
product certifications | C-Tick CE |
---|
Ambient air temperature for operation | 0…40 °C |
---|---|
relative humidity | 0…95 % |
Operating altitude | 0...3333 ft |
Ambient air temperature for storage | -35…60 °C |
storage Relative Humidity | 0…95 % |
Storage altitude | 0.00…15240.00 m |
Acoustic level | 64 dBA |
Heat dissipation | 1501 Btu/h |
IP degree of protection | IP20 |
Efficiency | View Efficiency Graph |
---|---|
Number of battery filled slots | 0 |
Number of battery free slots | 0 |
Battery recharge time | 5 h |
Additional information | Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage |
Battery power in VAH | 0 VAh runtime |
Battery life | 3…5 year(s) |
Extended runtime | 0 |
Free slots | 0 |
---|---|
Preinstalled device | Network management card with environmental monitoring |
control panel | Multifunction LCD status and control console |
Alarm | Audible and visible alarms prioritized by severity |
Emergency power off | Yes |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 129 cm |
Package 1 Width | 111 cm |
Package 1 Length | 72 cm |
Package 1 Weight | 173 kg |
Number of Units in Package 3 | 1 |
Warranty | 1 year on-site repair or replace with factory authorized Start-Up |
---|
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.
SUVTP10KH is replaced by: