PresentationHighly compact, energy efficient 3-phase UPS for data center, facility and industrial applications. to be used with external battery cabinets. Please click here for additional runtime information.
Lead timeUsually Ships within 2 Weeks
Main
Main Input Voltage400 V 3 phases
Other Input Voltage380 V
415 V
Main Output Voltage400 V 3 phases
Other Output Voltage380 V
415 V
Rated power in W180 kW
Rated power in VA200 kVA
output connector typeHard wire 4-wire (3P + E) 1
Hard wire 5-wire (3P + N + E) 1
Battery typeExternal battery system
provided equipmentBuilt-in modbus protocol adapter
Dust filter
Installation guide
Integrated network management
Seismic compliance
Top and bottom cable entry
General
Bypass voltage tolerance+/- 10 % settable from +/- 4/6/8 and 10 %
Max bypass input current289 A
Bypass current protection400 A
RedundantNo
Physical
colourWhite
Height197 cm
Width105.2 cm
Depth85.4 cm
Net weight724 kg
USB compatibleNo
Input
network frequency40...70 Hz
input voltage limits250...600 V adjustable
320...456 V 380 V
320...480 V 400 V
320...498 V 415 V
Maximum input current328 A
Switching current capacity400 A
Max short time withstand current65 kA
Input harmonic distortionLess than 3 % for full load
Input protection typeGL fuse
Inrush current200 A peak
Load power factor0.5 leading to 0.5 lagging
Input Power Factor at Full Load1
Output
Maximum configurable power in W180 kW
Harmonic distortionLess than 2 %
output frequency50/60 Hz +/- 1 Hz sync to mains
50/60 Hz +/- 1 Hz unsynchronised
Crest factorUnlimited
Wave typeSine wave
Output voltage tolerance+/- 1% static and +/- 3% at 100% load step
Output harmonic distortion< 2% linear load and < 3% non-linear load
Output overload operation10 minutes at 125% and 60 seconds at 150%
Neutral output current289 A
Bypass typeBuilt-in static bypass
Maximum configurable power in VA200 kVA
Conformance
product certificationsC-Tick
CE
RCM
StandardsEN/IEC 62040-1
EN/IEC 62040-2
EN/IEC 62040-3
IBC 2012 and CBC2013 to Sds=2.02g
ISTA 2B
OSHPD
UL 1778
Environmental
Ambient air temperature for operation0…40 °C
relative humidity0…95 %
Operating altitude0...3333 ft
Ambient air temperature for storage-25…55 °C
storage Relative Humidity0…95 %
Storage altitude0.00…14999.82 m
Acoustic level65 dBA
Heat dissipation24570 Btu/h
IP degree of protectionIP20
Batteries & Runtime
EfficiencyView Efficiency Graphaction_new_window
Number of battery filled slots0
Battery voltage480 V
discharge battery voltage384 V
Max current discharge393 A
Battery power in VAH0 VAh runtime
Extended runtime0
Communications & Management
Free slots2
control panel7" touch screen display
AlarmAudible and visible alarms prioritized by severity
Emergency power offYes
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height215.6 cm
Package 1 Width106 cm
Package 1 Length149 cm
Package 1 Weight770 kg
Contractual warranty
Warranty1 year on-site repair or replace with factory authorized Start-Up
arrow2_down

Sustainability

Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn morearrow2_left
Resource performance

Energy efficient product

notification_ok

Take-back program available

notification_ok
Well-being performance

Mercury free

notification_ok

RoHS exemption information

EU RoHS Directive

Environmental Disclosure

Circularity Profile

arrow2_down

Documents

arrow2_down

Software and Firmware

Need more information? Check our technical FAQs!