Specifications
Lead time | Usually Ships within 2 Weeks |
---|
Run time for load WEnter the total load (power draw) of all devices that will be protected by the UPS. This will be used to estimate the run time of your devices during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down. Min-max: 1200-12000 W | |
---|---|
Max. Capacity Used The maximum percentage of UPS capacity used to support your specified load. | |
Main Input Voltage | 400 V 3 phases |
Other Input Voltage | 380 V 415 V |
Main Output Voltage | 400 V 3 phases |
Other Output Voltage | 380 V 415 V |
Rated power in W | 12000 W |
Rated power in VA | 15000 VA |
Output connector type | Hard wire 4-wire (3P + E) 1 Hard wire 5-wire (3P + N + E) 1 |
Connections - terminals | 1 screw terminals |
Battery type | Lead-acid battery |
Provided equipment | Battery modules ship installed Bolt down brackets CD with software Installation guide Network management card Power modules ship installed Smart UPS signalling RS-232 cable Start-up service User manual |
Number of power module free slots | 0 |
---|---|
Number of power module filled slots | 0 |
Redundant | No |
Height | 149 cm |
---|---|
Width | 52.3 cm |
Depth | 84.2 cm |
Net weight | 535 kg |
Mounting preference | No preference |
USB compatible | No |
Network frequency | 40...70 Hz auto-sensing |
---|---|
Number of input connectors | 1 hard wire 5-wire (3P + N + E) |
Input voltage limits | 304...477 V |
Maximum input current | 20 A |
Switching current capacity | 25 A |
Input harmonic distortion | Less than 5 % for full load |
Input protection type | 3-pole circuit breaker |
Inrush current | 200 A peak |
Load power factor | 0.5 leading to 0.5 lagging |
Input Power Factor at Full Load | 0.98 |
Maximum configurable power in W | 12000 W |
---|---|
Harmonic distortion | Less than 5 % |
Output frequency | 47...53 Hz for 50 Hz nominal sync to mains 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised |
Crest factor | Unlimited |
Wave type | Sine wave |
Output voltage tolerance | +/- 5% static and 100% load step |
Output harmonic distortion | < 2% for 0 to 100% linear load and < 5% for full non-linear load |
Output overload operation | 10 minutes at 125% and 60 seconds at 150% |
Required output current protection | 25 A |
Bypass type | Built-in maintenance bypass Built-in static bypass |
Efficiency | 95.1 % (in battery operation) |
Maximum configurable power in VA | 15000 VA |
Product certifications | CE |
---|---|
Standards | EN 50091-2 EN/IEC 62040-3 EN/IEC 62040-1-1 IEC 61000-3-2 IEC 61000-3-3 ISO 14001 ISO 9001 VFI-SS-111 |
Ambient air temperature for operation | 0…40 °C |
---|---|
Relative humidity | 0…95 % |
Operating altitude | 0...3333 ft |
Ambient air temperature for storage | -15…45 °C |
Storage Relative Humidity | 0…95 % |
Storage altitude | 0.00…15240.00 m |
Acoustic level | 51.3 dBA |
heat dissipation | 1842 Btu/h |
IP degree of protection | IP51 |
Run Time | View Runtime Graph |
---|---|
Efficiency | View Efficiency Graph |
Number of battery filled slots | 3 |
Number of battery free slots | 1 |
Battery recharge time | 5 h |
Number of battery replacement quantity | 3 |
Additional information | Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage |
Battery voltage | +/- 192 V (split battery referenced to neutral) |
Discharge battery voltage | +/- 154 V |
Battery overload operation | 10 minutes at 125% and 60 seconds at 150% |
Battery charger power | 1482 W rated |
Battery power in VAH | 7424 VAh runtime |
Battery life | 3…5 year(s) |
Battery option | SYBT4 1 9810 VAh G35TBXR6B6 1 22197 VAh G35TBXR6B6 2 37079 VAh G35TBXR6B6 3 51910 VAh G35TBXR6B6 4 66966 VAh |
Battery graph comments | Estimated runtimes based on battery vendor data, at typical environmental conditions, with no electrical input and balanced PF = 0.8 output. |
Extended runtime | 0 |
Free slots | 0 |
---|---|
Preinstalled device | Network management card 2 with environmental monitoring |
control panel | Multifunction LCD status and control console |
Emergency power off | Yes |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 164.3 cm |
Package 1 Width | 106.2 cm |
Package 1 Length | 65 cm |
Package 1 Weight | 566 kg |
Warranty | 1 year repair or replace |
---|
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance.
Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn moreEU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.
G35T15KH3B4S is replaced by: