ACSC1XX Spare Parts List
CABLE ASSY TEMPERATURE SENSORS ( Rack Inlet) ... CAP MTL PPR 400v 5% 40uf RD (compressor) ... Ceiling Tile Adapter 24 " - Spare Part ... CONVERSION TO TOSHIBA COMP KIT , SC, 50hz - SPARE PART ... DUCTING KIT 24 INCH IR5 ... EVAPORATOR FAN MODULE ASSY - 17 KW IR ... InRow RC/SC Filter 1/2" Washable - Spare Part (default)
ACRP1XX, ACRD5XX, ACRP5XX, and ACRC5XX Parts List
... the fan grill module ] ... 13 FT ( RACK INLET ... Power 208/ 400v For acrp100/ ... ... Variable Frequency Drive 400v for acrp101 ( ... ... -0990 Fan Module Assembly 200v - ... -9841 Fan Module Assembly 400- ... ... acrp101 (DX 400v ) ... DX 200/ 400v ) ... u2311301 GASKET FOR INROW CW 3- ... ... KEY) ( Rack ) w0h- ... BLK SX ( Rack ) w0h- ... ... -0976 Reheat Module for 200v acrp100 ... -0813 Reheat Module for 400- ... ... JUMPER 0w2541 WIRE ASSY FM 380v JUMPER 0w2542 WIRE ASSY FM 400v JUMPER 0w2543 WIRE ASSY FM ...
Where can I get support for APC and MGE Products?
Basic Rack PDU ... Data Center Facility Cooling - Andover Continuum or TAC Vista ... Desktop Notebook Stands ... Fluid Coolers ... High-Density Cooling Enclosures ... InRow Chilled Water InRow Direct Expansion InRow Pumped Refrigerant ... Metered Rack PDU Metered-by-Outlet Rack PDU ... Microsol Modules Isoladores Mobile Notebook Stands ... NetBotz Rack Access ... NetShelter Open Frame Rack Accessories ... Open Frame Racks ... Portable Cooling ... Rack Air Distribution Rack Components Rack LCD Consoles Rack PDU Accessories Rack -mount Transfer Switches ... Room Cooling Accessories ... Row Cooling Accessories ... Switched Rack PDU ... Symmetra Power Module ... Uniflair Chilled Water
UPDATED MARCH-2016: Unable to access my APC Network Management Card (NMC) enabled device via HTTPS (SSL/TLS)
(via your local APC Cooling Support team) raru ACFXXX Rack Air Removal Unit ... ACRD1XX, ACRD2XX InRow RD AOS v3.9 ...
What is the input voltage required for the InRow ACRD?
What is the input voltage required for the InRow ACRD? ... InRow Cooling ... The InRow ACRD unit uses a single phase 208v/60hz input in NAM and a 230v/ 50hz input in the rest of the world.
APC Schneider Cooling Unit Identification
APC Cooling Unit identification. All Cooling Units. Module ... W= Water Cooled ... F= Water Cooled ... D= Water Cooled ... G= Glycol Cooled ... B= Glycol Cooled ... P= Glycol Cooled Module ... coil C= Chilled Water C= Chilled Water Module ... Main C= Chilled Water Module ... W= Water Cooled ... G= Glycol Cooled BA=208 ... ... W= Water Cooled ... G= Glycol Cooled ... W= Water Cooled ... G= Glycol Cooled ... W= Water Cooled ... F= Water Cooled w/Multicool ... G= Glycol Cooled ... B= Glycol Cooled w/Multicool
What are some of the applications for the InRow ACRD?
... applications for the InRow ACRD? InRow Cooling The InRow RD is an InRow air conditioner designed ... ... replace old legacy cooling methods with newer ... The InRow RD is a great option with its ... of close coupled cooling . ... platform, new cooling problems arise in ... The InRow RD allows for more predictable cooling in this new ... ... the demand for cooling will increase. ... Typical data center cooling looks at the ... The InRow RD is controlled ... modes using a rack inlet temperature probe ... ~ The InRow RD provides the ... makes it a great choice for customers with long term growth plans ...
InRow RC Standard and Optional Features
InRow RC Features ... InRow RC ... Data Center Cooling ... 1-The Standard Features of the InRow Rc Coolling Unit are as follow: ... Chilled Water Flow Meter ... Baying Kit InRow RC to NetShelter VX rack ... Power Trough (Overhead power distribution between racks )
APC KVM Switches and Corresponding Cables/Server Modules
APC KVM Part Numbers and Corresponding Cables/Server Modules ... G, Server Module , USB ... G, Server Module , PS/ ... ... G, Server Module , USB ... G, Server Module , PS/ ... ... G, Server Module , USB with ... ... G, Server Module , PS/ ... ... G, Server Module , USB with ... ... G, Server Module , Serial ... set of server modules and cabling. ... /2 Server Module ... KVM USB Server Module ... KVM SUN Server Module ... /2 Server Module ... KVM USB Server Module ... KVM SUN Server Module ... USB VM Server Module ... 2 VM Server Module ... vt100 Serial Server Module
Why are the red outlet LEDs always scrolling on Rack PDU models AP7855 or AP7867?
AP78XX Metered Rack PDU models, specifically ... Connect a known load (must be greater than 5A) on L1 Outlet 2. Then select the fourth menu "Calibrate the unit". ... If the outlet load reads 2.4 amps without load then provide the value as '- 24 '.