Browse FAQs



How do I hardwire 10kva and 20kva transformers in a 208/120 or 240/120 environment
You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are ...
Hardwiring to 120v, 208v, and 240v loads from a 208v/240v SmartUPS RT UPS
These two models are split phase 4 ... /Neutral/Ground) units and do not require a stepdown transformer to support 120v loads.
Spare parts list for ACRD1XX, and ACRD2XX
... PART 9. 600 195.0 2 ,000. ... ... CRAC 8X 2 FORM-C ... 2 .505 210 ... DP 2 POLE 30a 208- ... ... VALVE 1/ 2 " 208 1/ 2 "ODF SOLDER ... 1/ 2 " ODF - ... 1/ 2 "ODM X ... .0 w920-0082 DC RECTIFIER 500w - SPARE PART 2 .493 214.0 130.0 332.0 2 .013 130.0 72 .0 275.0
Symmetra Power Array Input Voltage Selector Theory of Operation
The input voltage selector switch is primarily responsible for two things: routing power through the appropriate taps of the isolation transformer and notifying the ...
Installation with Single / 2-Pole or 3/4 Pole MCB’s
it doesn’t make sense to modify the distribution board to accommodate other breakers types.
50a 208v 3 Phase Rack PDU Load Ratings and Calculations Explained
50a 208v 3 Phase Rack ... ... Phase Rack Power Distribution models ... each bank references two phases: ... Phase 1 and 2 Bank 2 - Phase 2 and 3 ... of the few units where the capacity ... ... phases 1 and 2 simultaneously. Bank 2 draws current from phases 2 and 3. ... means that phase 2 is supplying current ... banks 1 and 2 . However, ... ... direction on bank 2 and the two currents increase the draw from phase 2 to over 20a ... returned on bank 2 . This means ... ... loads on the two banks to get ... load on phase 2 .
Video: How do I configure a 208v Smart-UPS RT or SRT for use with a 240v input?
... I configure a 208v Smart-UPS ... ... RT and SRT units sold in North ... factory configured for 208v in/out ... ... By default the unit will accept the ... continue to provide 208v output. This can be done via a Hyper terminal session, or more commonly using the Network Management Card interface. ... If you need 120 v for your equipment you will still need to use a stepdown transformer . The Stepdown Transformer must allow for 240v input, such as the surt003 ... The AP9626, AP9627, and AP9628 would not be appropriate as they are designed for 208v input only.
Can cable bridge partition/trough be installed across the top of a 300 mm or 600 mm InRow chilled water cooling unit?
... the InRow cooling unit . ... , Row Power Distribution ... chilled water cooling units so there's nowhere ... Please use acac10005 for 300 mm wide applications and acac10010 for 600 mm wide applications. ... A NetShelter trough such as ar8580 or AR8561 may also be used to span the cooling unit but they can not be attached directly to them. NetShelter troughs can span one cabinet width without attaching directly to the cooling unit roof. See the installation manual of the NetShelter trough, instruction # 2 .
Verification of Matrix-UPS input voltage configuration
2 ) Next, go to the menu UPS Diagnostics ... ; on this sub-menu screen will be the revision of the Electronic Unit's UPS control microprocessor. ... , the Matrix-UPS Input Voltage Select Wire is attached to the 208v tap; therefore, the input voltage should be approximately 208v . ... If this is not done, the Matrix-UPS will either stay in bypass mode or constantly change its transformer taps.


Results 1 - 10 of 50

Can't find what you are looking for?

Reach out to our customer care team to receive information on technical support, assistance for complaints and more.