    ACSC1XX Spare Parts List
    CAP MTL PPR 400v 5% 40uf RD (compressor) ... CONVERSION TO TOSHIBA COMP KIT , SC, 50hz - SPARE PART ... EVAPORATOR FAN MODULE ASSY - 17 KW IR ... GROMMET RUBBER 1 1/2"ID X 1 3/4"GD X 1/8"GW (for power cable at the bottom)
    Symmetra PX 250/500 Battery to Power Module Ratio
    The 250kw runtime ratio is 10 PMs to 16 battery shelves resulting in a ratio of 1.6 battery shelf per 1 PM. ...
    ACRP1XX, ACRD5XX, ACRP5XX, and ACRC5XX Parts List
    ... the fan grill module ] ... w0w3107 Cable Main Power 208/ 400v For acrp100/ ... ... w0w3128 Cable Main Power 480v For acrp101 ... ... w0w3127 Cable Main Power acrp5xx ASSY ATS ... 0w3125 Cable Main Power acrp5xx ASSY ATS ... ... Variable Frequency Drive 400v for acrp101 ( ... ... -0990 Fan Module Assembly 200v - ... -9841 Fan Module Assembly 400- ... ... acrp101 (DX 400v ) ... DX 200/ 400v ) ... (SIMM Card power control board ... - (CMS power control board ... -0976 Reheat Module for 200v acrp100 ... -0813 Reheat Module for 400- ... ... WIRE ASSY FM 400v JUMPER 0w2543 WIRE ...
    Information on Online and On Battery operation of 3:1 Symmetra UPS systems
    Symmetra Power Array ... When a Symmetra 3:1 is operating On-Line it is drawing balanced power from all 3 phases, i.e., it is drawing the same current from each of the 3 phases. ... The 3 phase power is fed to all the Power Modules where it is filtered and converted to single phase and sent to the output. ... When Symmetra 3:1 is On Battery it will provide single phase output power . ... The output frequency can also be set to either 50hz or 60hz.
    How do I replace a single phase Symmetra power module?
    Issue What is the proper procedure for installing a replacement power module in a single phase Symmetra UPS system?
    Symmetra LX shows site wiring fault and/or has clicking power modules
    Symmetra LX runs on battery and may exhibit audible clicking from the power modules . Erroneous messages regarding output voltage may also occur.
    Why does my Symmetra PX UPS show a power module status of NA when first installed?
    Issue Symmetra PX UPS shows power module status as "NA" within the Network Management Card interface when the module is first installed
    Can I install battery modules in the power module bays with my Symmetra RM 2-6kva UPS?
    SYBT2) in the bottom three power module bays to provide additional runtime if the bays are not being occupied by power modules .
    Compatibility Information for Symmetra Power Array 3:1 Modules
    ... firmware changes necessary to make the Symmetra Power Array 3:1 system function properly, it requires specific intelligence modules and power modules .
    Video: Symmetra Power Array Module Replacement Procedure
    Resolution The following videos detail the process of replacing the Battery and Power Modules in the Symmetra Power Array UPS.