Technical FAQs

Ask a Question

Filter results

    NetBotz Room Monitor 355/455 POE Power Specifications
    Issue: NetBotz Room Monitor 355 /455 POE Power Specifications
    NetBotz 355 | Physical Description
    ... Description of the NetBotz 355 and 355A NetBotz version 3 - Wall Monitor 355 - Wall Monitor 355A NetBotz 355 /355A ( ... Third-party dry-contact state sensors require the NetBotz Dry Contact Cable (nbes0304). Standard third-party 0-5 V sensors require the NetBotz 0-5 V Sensor Cable (nbes0305). 2 10/100 Base-T network port Provides for a 10/100 Base-T network connection and power through Power-over-Ethernet ( PoE ). ... The complete NetBotz 455 Installation and Quick Configuration Manual can be found .
    NetBotz | End of Sale & End of Support Information
    NetBotz - End of ... NetBotz (all models ... NetBotz Central NetBotz (all versions ... NetBotz End of Sale ... AP9319 Environmental Monitoring Unit July 2006 ... nbrk0200 / nbrk0201 NetBotz Rack Monitor 200 October 2016 ... ​NBACS1356 NetBotz 320 NetBotz 320 Rack Mount ... July 2014 nbrk0750 NetBotz 320 Wall Mount ... nbwl0356a NetBotz 320 Environmental July ... July 2017 nbrk0750 NetBotz 420 NetBotz 420 Rack Mount ... May 2014 nbrk0750 NetBotz 420 Wall Mount ... nbwl0456a NetBotz 420 Environmental May ... May 2017 nbrk0750 NetBotz 500 NetBotz 500 Wall Mount ...
    Power Over Ethernet configuration supported by NetBotz products.
    Alternative 'B' is more often used by a midspan device such as a POE injector .
    APC POE Injector | Installation Instructions
    POE Injector Installation, Netbotz , nbac0303, manual
    Can I use a NetBotz Camera Pod 160 nbpd0160 / nbpd0160a as a standalone appliance?
    Purchase a Rack Monitor 450, 550, or 570, or Room Monitor 455 for functionality.
    NetBotz 455 | Physical Description
    ... Description of the NetBotz 455 and 455A NetBotz version 3 - Wall Monitor 455 - Wall Monitor 455A NetBotz 455/455A ... ... Used for cascading NetBotz sensor pods and ... ... -Ethernet ( PoE ). Third-party dry-contact state sensors require the NetBotz Dry Contact Cable (nbes0304). Standard third-party 0-5 V sensors require the NetBotz 0-5 V Sensor Cable (nbes0305). ... The complete NetBotz 455 Installation and Quick Configuration Manual can be found .
    NetBotz v2 | Why does Netbotz Advanced Device Crawlers show no environmental data on a Cisco 3524 Switch
    Why do Netbotz Advanced Device Crawlers show no environmental data on a Cisco 3524 Switch? ... NetBotz (NB) v2 (320, 420, & 500) NetBotz (NB) v3 ( 355 , 355 , 450, 455, 550, & 570) ... NetBotz NetBotz Device Monitoring Pack (license) ... The Cisco 3524 switch does not publish environmental data via the SNMP agent, therefore; Netbotz Advanced Device Crawlers does not show any environmental information for the device.
    NetBotz 750 camera thumbnail must be manually deleted from surveillance view in StruxureWare Data Center Expert
    NetBotz 750 camera thumbnail ... NetBotz 75x ... NetBotz 750 / 755 version 5.2 firmware with a camera pod 165 in Surveillance View of DCE 7.7 ... Cameras are added to DCE in a different manner on a NetBotz nbrk0750 or nbwl0755 ... When you remove a version 2 or 3 NetBotz appliance with a camera pod 120 or 160 from a DCE server, the camera thumbnail will automatically be removed with the device. This is not the case with the NetBotz camera pod 165. Even after you remove the appliance from the monitoring perspective of DCE, the camera thumbnail will remain.
    Adding a USB-based light to a NetBotz 420 or 500
    ... light to a NetBotz 420 or 500 NetBotz NetBotz version 2. NetBotz strongly recommends that ... night cameras to monitor low-light ... unsupported parts to NetBotz appliances. NetBotz Development Team also ... corner of the room , to avoid ... Another ungraceful, unsupported option is to remove the IR filter from behind the lens, and replace it with a clear filter, add an external IR illuminator box to the room . ... Please note that all the above options are do-able but are NOT supported by NetBotz
    Results 1 - 10 of 50