Browse FAQs



DAC, Cancoil Installation Manual
Section 1 . Warranty and General Information ... ... please visit our website at www. ... Section 1 . ... provided in the unit . DO ... SECTION OF THE UNIT . ... not use the refrigerant piping as a ... Unit Placement and Mounting ... unit should be securely ... ... clearance around the unit for proper servicing ... ... Catalog Products Limited Warranty ... catalog products limited warranty . ... are based on 1 degree per 100 ... ... a rate of 1 ” drop per ... ... winter charge ( page 8) plus ... ... a rate of 1 ” drop per ... ... and should have 1 additional trap per ...
How to navigate through an Network Air FM unit display
... Network Air FM unit display. ... Relays” on page 25 to set ... ... work as a single System. ... Half capacity uses one compressor and half ... When the unit is in dehumidification ... All refrigerant is directed through ... Refrigerant . ... the type of refrigerant charge used in ... ... out into the refrigerant line. ... out into the refrigerant line. ... and then keeps coolant flowing through the ... ... compressor (stage 1 ) in a ... ... is adequate liquid coolant (glycol or ... ... switch detects inadequate coolant flow at the ... ... the flow of coolant into the heat ... ... the flow of coolant to either the ...
Can you interconnect A-Links CW and DX InRow Cooling products?
1 ) Cannot ... Just to clarify, it's "like" units , so 600mm DX with other 600mm DX; and 600mm CW with other 600mm CW; however, 600mm CW and 600mm DX can NOT be grouped, even though they share the same FW. ... Pumped Refrigerant Cooling System (PRCS, r134a ...) ... For 300mm Units and Pumped Refrigerant :
Where can I get support for APC and MGE Products?
Cabinet Power Distribution ... Configurable Power Distribution ... Data Distribution Cable ... DC Distribution Components ... Environmental Monitoring Unit ... InRow Pumped Refrigerant ... Modular Power Distribution ... On Site Service ... Power Distribution Units ... Refrigerant Distribution ... Stationary Power Distribution Units
APC Security Advisory - InfraStruxure Central 5.0 Java Runtime Environment
[ 1 ] ... some files and web pages ) or a ... ... downloaded from a website unauthorized access to ... some files and web pages ). ... Central Client uses one font throughout all ... ... downloaded from a website to create arbitrary ... ... downloaded from a website to create or ... ... in Java Management Extensions (JMX) ... ... the Java Management Extensions (JMX) ... ... downloaded from a website to elevate its ... ... other than the one that the applet ... ... ALTHOUGH APC CANNOT GUARANTEE THE ACCURACY OF ... ... THAT OMITS THE DISTRIBUTION URL IN THE ... Distribution ... posted to APC's website .
Installation Manual for the acda901
acda901, RDU , install manual, installation, manuals, pumped refrigerant
Oil Type for Different Types of Refrigerant
Oil Type for Different Types of Refrigerant ... All AC DX Units ... Below is a list of the different oil types for the different refrigerants in our units . Always check the compressor manufacture’s recommendations for oil on any other type of cooling unit . ... Units : AFX, CM, CCT, DT, TC, FM, acpa4000, ap7003 R134A Use POE oil Units : RDU but no oil needed for this unit on startup. ... Units : ACRP, acrd5xx, Stulz ... Units : ACRD1XX, ACRD2XX, ACRD3XX,acrd60xx, ACRD6XXP ACSC, Uniflair, ACPSC, Ecobreeze
Refrigerant charging table for a Uniflair Unit
Refrigerant charging table for a Uniflair Unit . ... -cooled DX units must be connected ... Install all refrigerant lines in accordance ... • All refrigerant piping is type ... • All refrigerant lines/chilled ... • All refrigerant lines should be ... • All refrigerant piping joints must ... • All refrigerant pipes are installed ... supports and approved refrigerant line clamps. ... lines and the refrigerant connections must be ... ... sized such that refrigerant velocity in vertical ... Refrigerant velocity in horizontal ... Refrigerant velocity must be ... If refrigerant velocity is too ... If the refrigerant velocity is too ... ... to ensure sufficient refrigerant flow to the ...
How accurate is the current monitor on my APC Rack Power Distribution Unit (PDU) and Rack Automatic Transfer Switch ?
... APC Rack Power Distribution Unit (PDU) ... Rack Power Distribution ... to Outlet # 1 (phase L 1 ). 0- 1 A 1 -10a ... attached loads < 1 amp will always ... +/- 1 least significant digit ... ... , since the unit does consume a ... ... , since the unit does consume a ... ... 3% + 1 digit) Accuracy ... 3% + 1 digit) Accuracy ... + 1 digit) Accuracy ... 3% + 1 digit) Accuracy ... ... 3% + 1 digit) ... +/- 1 least significant digit ...
Liquid Charging an InRow 600mm Refrigerant Based System
... an InRow 600mm Refrigerant Based System 1 ) Close the ... ... with the vacuum pump . 4) Carefully open the valves on the low-/high-pressure sides and service port (rp10x & rd50x) to activate the vacuum pump . ... 6) Calculate the total charge needed ... Indoor Unit Charge + Liquid Line Charge + Condenser Charge = Total Charge 7) Charge with liquid, preferably at the outdoor receiver, until the system pressure equalizes with the refrigerant canister. ... b. Purge the refrigerant hoses and manifold set.


Results 1 - 10 of 50

Can't find what you are looking for?

Reach out to our customer care team to receive information on technical support, assistance for complaints and more.