RDX Remote Fluid Cooled Condenser InRow DX 600mm
- Document Date: 19/09/2008
- Reference: SPD_JBEN-777HJP_EN
- Description: The InRow DX 600mm Series of InRow DX cooling products has been designed for use with remote air-cooled condensers, and is supported by a variety of c...
- Size: 493.8 kb
- Version: V1
- Language: English
-
Best Practices for Deploying the InfraStruXure InRow SC
- Document Date: 22/02/2007
- Reference: SPD_DRON-6X6VMS_EN
- Description: The InfraStruXure® InRow™ SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets. This application note outl...
- Size: 2 mb
- Version: V0
- Language: English
-
Application Guidelines for the InfraStruXure InRow SC Condenser
- Document Date: 21/12/2006
- Reference: SPD_DRON-6WEQ3G_EN
- Description: The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets. This application note outlin...
- Size: 891.6 kb
- Version: V0
- Language: English
-
UPS Power for the InfraStruXure InRow SC
- Document Date: 22/05/2007
- Reference: SPD_DRON-6WGT5E_EN
- Description: The InfraStruXure® InRow™ SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets. This application note outl...
- Size: 122.8 kb
- Version: V0
- Language: English
-
Configuration Types and Sequence of Operations for the InfraStruXure InRow SC
- Document Date: 10/09/2013
- Reference: SPD_DRON-6X6VG3_EN
- Description: The InfraStruXure® InRow™ SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets. This application note outl...
- Size: 208.4 kb
- Version: V0
- Language: English
-
Pump Selection for InRow Glycol-Cooled Unit System ACRD20X
- Document Date: 17/07/2009
- Reference: SPD_KSIH-7S7TU3_EN
- Description: While pump packages are not directly supported from APC, a minimal design effort is required for the installer to select the necessary components to d...
- Size: 426.8 kb
- Version: V0
- Language: English
-
ACRP Requirements for Selecting 3rd Party Remote Air-Cooled Condenser and Flooded Receiver
- Document Date: 30/03/2007
- Reference: SPD_KSIH-6Y6SJP_EN
- Description: The InfraStruXure InRow RP (ACRP100, ACRP101, and ACRP102) is an air-cooled DX air conditioner for data centers. All air-cooled air conditioners requi...
- Size: 497 kb
- Version: V0
- Language: English
-
Using MCA and MOP Ratings to Safely Connect Your Field Wired Air Conditioner
- Document Date: 13/03/2007
- Reference: SPD_KSIH-6Y6UU5_EN
- Description: The minimum circuit ampacity (MCA) and maximum overcurrent protection (MOP) ratings provide guidance for safely connecting field-wired equipment to th...
- Size: 161.1 kb
- Version: V0
- Language: English
-
Guidelines for Using Rack Air Containment System with InfraStruXure InRow SC
- Document Date: 09/03/2007
- Reference: SPD_DRON-6X6VCB_EN
- Description: The InfraStruXure® InRow™ SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets. This application note prov...
- Size: 249.4 kb
- Version: V0
- Language: English
-
ACRP Remote Air-Cooled Condenser Application and Placement
- Document Date: 11/06/2007
- Reference: SPD_KSIH-6Y6TNH_EN
- Description: The InfraStruXure InRow RP (ACRP100, ACRP101, and ACRP102) is an air-cooled DX air conditioner for data centers. All air-cooled air conditioners requi...
- Size: 515.6 kb
- Version: V0
- Language: English