APC Silcon 10kW 208V UPS
SL10KF
Discontinued on:31 December 2010
End-of-service on:31 December 2018
SL10KF has not been replaced. Please contact your customer care center for more information.
Compatible Software
Specifications
Lead time | While Supplies Last |
---|
Main Input Voltage | 208 V 3 phases |
---|---|
Main Output Voltage | 120 V 208 V 208 V 3 phases |
Rated power in W | 10000 W |
Rated power in VA | 10000 VA |
output connector type | Hard wire 5-wire (3P + N + E) 1 |
connections - terminals | 1 screw terminals |
Number of rack unit | 0U |
number of cables | 1 |
Battery type | External battery system |
provided equipment | Installation guide Parallel card Triple chassis for 3 SmartSlots User manual Web/SNMP management card |
Number of power module free slots | 0 |
---|---|
Number of power module filled slots | 0 |
Redundant | No |
colour | Dark green NCS 7020-B50G) Light grey NCS 2703-G84Y) |
---|---|
Height | 55.12 in (140 cm) |
Width | 23.62 in (60 cm) |
Depth | 31.50 in (80 cm) |
Net weight | 420.88 lb(US) (190.91 kg) |
Mounting location | Front |
Mounting preference | No preference |
Mounting mode | Not rack-mountable |
USB compatible | No |
network frequency | 50 Hz programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8 % 60 Hz programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8 % |
---|---|
number of input connectors | 1 hard wire 5-wire (3P + N + E) |
input voltage limits | 170...230 V 208 V 177...239 V 208 V 187...242 V 220 V |
Input Power Factor at Full Load | 0.99 |
Maximum configurable power in W | 10000 W |
---|---|
Harmonic distortion | Less than 3 % |
output frequency | 50 Hz programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8 % sync to mains 60 Hz programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8 % sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised |
Crest factor | Unlimited |
UPS type | Delta conversion on-line |
Wave type | Sine wave |
Bypass type | Built-in static bypass |
efficiency | 93.6 % full load) |
Maximum output current | 28 A |
Maximum configurable power in VA | 10000 VA |
product certifications | cUL listed UL listed |
---|---|
Standards | FCC part 15 class A ISO 14001 ISO 9001 UL 1778 |
Ambient air temperature for operation | 32…104 °F (0…40 °C) |
---|---|
relative humidity | 0…95 % |
Operating altitude | 0...3333 ft |
Ambient air temperature for storage | -58…104 °F (-50…40 °C) |
storage Relative Humidity | 0…95 % |
Storage altitude | 0…50000 ft (0.00…15240.00 m) |
Acoustic level | 55 dBA |
Heat dissipation | 2388 Btu/h |
NEMA degree of protection | NEMA 1 NEMA 12 optional) |
Number of battery filled slots | 0 |
---|---|
Number of battery free slots | 0 |
Additional information | A Battery Breaker Box is required for all 10kW External Battery Solutions. Configurable for 200 : 208 or 220V 3 Phase nominal output voltage |
Battery power in VAH | 0 VAh runtime |
Extended runtime | 1 |
Free slots | 2 |
---|---|
Preinstalled device | Network management card |
control panel | Multifunction LCD status and control console |
Alarm | Beep for each 52 alarm conditions |
Emergency power off | Yes |
Warranty | 1 year (parts only), optional on-site warranties available, optional extended warranties available |
---|