Specifications
Presentation | A highly efficient, modular, 1500 kVA 3-phase UPS that provides the performance, flexibility, and maximized asset utilization today’s large data centers and mission critical applications require. This EcoStruxure Ready UPS features up to 99% efficiency with patented ECOnversion technology. Includes 5x8 start-up service. |
---|---|
Lead time | Special Order - Call for Quoted Lead Times |
Main Input Voltage | 480 V 3 phases |
---|---|
Main Output Voltage | 480 V 3 phases |
Rated power in W | 1500 kW |
Rated power in VA | 1500 kVA |
Battery type | External battery system |
provided equipment | Installation guide Start-up service |
Redundant | No |
---|
colour | White |
---|---|
Height | 77.56 in (197 cm) |
Width | 220.47 in (560 cm) |
Depth | 35.43 in (90 cm) |
Net weight | 8796.45 lb(US) (3990 kg) |
USB compatible | No |
network frequency | 40...70 Hz |
---|---|
Maximum input current | 2184 A |
Max short time withstand current | 100 kA |
Input harmonic distortion | Less than 3 % for full load |
Load power factor | From 0.7 leading to 0.5 lagging without any derating |
Maximum configurable power in W | 1500 kW |
---|---|
output frequency | 60 Hz sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised |
Crest factor | 3 with THC <5% |
Wave type | Sine wave |
Output harmonic distortion | < 2% linear load and < 3% non-linear load |
Output overload operation | 10 minutes at 125% and 60 seconds at 150% |
Maximum configurable power in VA | 1500 kVA |
standards | CBC 2013 to Sds = 1.84g CSA C22.2 No 107.3 FCC part 15 class A IBC 2012 IEC 62040-3 IEC 60721-4-2 level 2M2 OSHPD UL 1778 5th edition |
---|
Ambient air temperature for operation | 32…104 °F (0…40 °C) |
---|---|
relative humidity | 0…95 % non-condensing |
Operating altitude | 0...3333 ft |
Ambient air temperature for storage | 5…104 °F (-15…40 °C) |
storage Relative Humidity | Non-condensing 0…95 % |
Storage altitude | 0…50000 ft (0.00…15240.00 m) |
Acoustic level | 68 dBA |
Heat dissipation | 207702 Btu/h |
IP degree of protection | IP20 |
Efficiency | View Efficiency Graph |
---|---|
Number of battery filled slots | 0 |
Number of battery free slots | 0 |
Battery voltage | 480 V |
discharge battery voltage | 384 V DC |
Battery power in VAH | 0 VAh runtime |
Extended runtime | 0 |
Free slots | 2 |
---|---|
Preinstalled device | Network management card 2 with environmental monitoring, out of band access and Modbus |
Control panel | 7" touch screen display |
Alarm | Audible and visible alarms prioritized by severity |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 84.65 in (215 cm) |
Package 1 Width | 41.73 in (106 cm) |
Package 1 Length | 261.42 in (664 cm) |
Package 1 Weight | 11307.52 lb(US) (5129 kg) |
Warranty | 1 year on-site repair or replace with factory authorized Start-Up |
---|
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance.
Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn moreEU RoHS Directive
Under investigation
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.