MGE Galaxy 5500 30kVA 400-415V Integrated Parallel UPS Off Shore IP22 RAL 7035, Start-up 5X8
G55TUPM30HXS
Discontinued on:06 September 2021
To be end-of-service on:31 December 2030
Specifications
Presentation | UPS is designed to meet the offshore standard requirement. |
---|---|
Lead time | Special Order - Call for Quoted Lead Times |
Main Input Voltage | 400 V 3 phases |
---|---|
Other Input Voltage | 380 V 415 V |
Main Output Voltage | 400 V 3 phases |
Other Output Voltage | 380 V 415 V |
Rated power in W | 27000 W |
Rated power in VA | 30000 VA |
Battery type | External battery system |
provided equipment | Installation guide User manual |
Bypass wiring configuration | 4 wire (3P + N) 5 wire (3P + N + E) |
---|---|
Bypass voltage tolerance | +/- 10 % settable from +/- 4/6/8 and 10 % |
Max bypass input current | 43 A |
Bypass current protection | 100 A |
Number of power module free slots | 0 |
Number of power module filled slots | 0 |
Redundant | No |
Height | 85.83 in (218 cm) |
---|---|
Width | 28.03 in (71.2 cm) |
Depth | 33.66 in (85.5 cm) |
Net weight | 1005.31 lb(US) (456 kg) |
Mounting preference | No preference |
USB compatible | No |
network frequency | 45...65 Hz |
---|---|
number of input connectors | 1 hard wire 4-wire (3P + E) 1 hard wire 4-wire (3P + N) |
input voltage limits | 323...437 V 380 V 340...460 V 400 V 353...477 V 415 V |
Maximum input current | 60 A |
Switching current capacity | 125 A |
Max short time withstand current | 20 kA |
Input harmonic distortion | Less than 5 % for full load |
Input protection type | GL fuse |
Load power factor | 0.9 |
Input Power Factor at Full Load | 1 |
Maximum configurable power in W | 27000 W |
---|---|
Harmonic distortion | Less than 2 % |
output frequency | 50 Hz programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8 % sync to mains 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised |
Crest factor | 3 : 1 |
Wave type | Sine wave |
Output voltage tolerance | +/- 2% static and 100% load step |
Output harmonic distortion | < 1% linear load and < 2.5% non-linear load |
Output overload operation | 10 minutes at 125% and 60 seconds at 150% |
Required output current protection | 43 A |
Neutral output current | 65 A |
Bypass type | Built-in maintenance bypass Built-in static bypass Optional external bypass |
efficiency | 90 % full load) 84 % half load) |
Maximum output current | 190 A |
Maximum configurable power in VA | 30000 VA |
Product certifications | CE TÜV VDE |
---|---|
Standards | EN/IEC 62040-1 EN/IEC 62040-2 EN/IEC 62040-3 ISO 9001 |
Ambient air temperature for operation | 32…104 °F (0…40 °C) |
---|---|
relative humidity | 0…95 % |
Operating altitude | 0...3333 ft |
Ambient air temperature for storage | -4…113 °F (-20…45 °C) |
storage Relative Humidity | 0…95 % |
Storage altitude | 0…40000 ft (0.00…12192.00 m) |
Acoustic level | 65 dBA |
IP degree of protection | IP20 IP32 |
Number of battery filled slots | 0 |
---|---|
Number of battery free slots | 0 |
Additional information | Configurable for 400 or 415 V 3 Phase nominal output voltage |
battery charger power | 5600 W rated |
Battery power in VAH | 56 VAh runtime |
Battery life | 8…10 year(s) |
battery option | G55TE-BB30K30 1 23011 VAh |
Extended runtime | 0 |
Free slots | 3 |
---|---|
Preinstalled device | Network management card 2 with environmental monitoring, out of band access and Modbus - Schneider |
control panel | Multifunction LCD status and control console |
Emergency power off | Yes |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 90.55 in (230 cm) |
Package 1 Width | 47.24 in (120 cm) |
Package 1 Length | 42.52 in (108 cm) |
Package 1 Weight | 1058.22 lb(US) (480 kg) |
Warranty | 1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up |
---|
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance.
Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn moreEU RoHS Directive
Under investigation
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.