Reliability Analysis of the APC Symmetra MW Power System
- Document Date: 16/04/2010
- Reference: SPD_VAVR-6CWR9R_EN
- Description: This paper is a quantitative reliability analysis of the APC Symmetra MW UPS performed by MTechnology, Inc. (MTech)...
- Size: 324.7 kb
- Version: V1
- Language: English
-
Strategies for Deploying Blade Servers in Existing Data Centers
- Document Date: 25/05/2012
- Reference: SPD_NRAN-69M6RX_EN
- Description: When blade servers are densely packed, they can exceed the power and cooling capacities of almost all traditional data centers...
- Size: 1.2 mb
- Version: V2
- Language: English
-
Data Center Projects: Standardized Process
- Document Date: 25/05/2012
- Reference: SPD_DBOY-6KVM82_EN
- Description: As the design and deployment of data center physical infrastructure moves away from art and more toward science, the benefits of a standardized and...
- Size: 895.9 kb
- Version: V1
- Language: English
-
Electrical Efficiency Modeling for Data Centers
- Document Date: 16/04/2010
- Reference: SPD_NRAN-66CK3D_EN
- Description: Conventional models for estimating electrical efficiency of data centers are grossly inaccurate for real-world installations...
- Size: 1 mb
- Version: V2
- Language: English
-
Improved Chilled Water Piping Distribution Methodology for Data Centers
- Document Date: 20/04/2010
- Reference: SPD_VAVR-6HD39F_EN
- Description: Chilled water remains a popular cooling medium; however leaks in the piping systems are a threat to system availability...
- Size: 881 kb
- Version: V1
- Language: English
-
A Quantitative Comparison of High Efficiency AC vs. DC Power Distribution for Data Centers
- Document Date: 23/01/2015
- Reference: SPD_NRAN-76TTJY_EN
- Description: This paper presents a detailed quantitative efficiency comparison between the most efficient DC and AC power distribution methods, including an...
- Size: 744.8 kb
- Version: V4
- Language: English
-
Five Basic Steps for Efficient Space Organization within High Density Enclosures
- Document Date: 09/10/2015
- Reference: SPD_VAVR-7BQRS4_EN
- Description: Organizing components and cables within high density enclosures need not be a stressful, time consuming chore...
- Size: 52.1 kb
- Version: V2
- Language: English
-
Fundamental Principles of Generators for Information Technology
- Document Date: 31/03/2010
- Reference: SPD_SADE-5TNRPC_EN
- Description: Every Information Technology professional who is responsible for the operation of computing equipment needs to ensure their data center or network...
- Size: 557.4 kb
- Version: V1
- Language: English
-
Grounding and the Use of the Signal Reference Grid in Data Centers
- Document Date: 27/02/2012
- Reference: SPD_NRAN-6C25ZY_EN
- Description: Signal reference grids are automatically specified and installed in data centers despite the fact that they are no longer needed by modern IT...
- Size: 155.3 kb
- Version: V2
- Language: English
-
Electrical Efficiency Measurement for Data Centers
- Document Date: 25/05/2012
- Reference: SPD_NRAN-72754V_EN
- Description: Data center electrical efficiency is rarely planned or managed...
- Size: 1.2 mb
- Version: V2
- Language: English