What is the difference between an InRow RP, InRow RD (600mm), and InRow RC (600mm)?
The minimum required kW for 1 direct expansion unit is 12kw and 12kw for chilled water. There should also be a consideration regarding humidity control.
Refrigerant charging table for a Uniflair Unit
... Refrigerant charging table for a Uniflair Unit . ... -cooled DX units must be connected ... Systems with remote outdoor ... ... A5. 8 BCuP-5 ... ... failures due to system vibrations. ... of the refrigeration system during the brazing ... ... the following table for reference when determining ... ... oil throughout the system , in particular ... For pipes running in ... ... determine pipe diameter for vertical pipes. ... determine pipe diameter for horizontal pipes. 1 . Open any ... present in the system to ensure that ... ... . Pressurize the system to 17. ... ... . Leave the system pressurized for 24 hours.
Network Air FM unit spare parts list
ADAPTER ROTO 1 1 /4" ... 12R 7/ 8 "SWT ADAPTER ROTO 1 "-14R 7/ 8 "SWT ( indoor rec'r) CAT5 for EXP unit ... - MKC- 1 ... ASSY FM 35 KW DX ... ASSY FM 40 KW DX ... ASSY FM 50 KW DX ... compressor [K 1 & K2 ... ... DF 5/ Unit 756 X 325 ... X 12. 8 X 4IN) ... DF 5/ Unit 756 X 325 ... X 12. 8 X 4IN) ... FM35-50 KW W/AIR ... ... FM35-50 KW W/AIR ...
APC Schneider Cooling Unit Identification
APC Cooling Unit identification. All Cooling Units . APC Unit Identification Capacity KW Capacity KW Capacity KW Capacity KW Capacity KW Capacity KW 27 ( 8 T) AFX 1 = 1 Bay ... Bay 06 ( 1 Bay) 08 ( 1 Bay) Capacity KW ... CM 003 ( 1 T) ... -230/ 1 /60 ... =277/ 1 /60 1 -5T ... 1 -3T ... ... -230/ 1 /60 ... =277/ 1 /60 ... = Air Cooled Indoor Condenser ... = Air Cooled Indoor Condensing ... Air Cooled Remote Indoor Condensing
How to properly update an NetworkAIR FM NMC via XModem.
Open Hyper-Terminal Session / set to 9600, 8 , None, 1 , None ... From the control console enter: 3- System ... 1 -XMODEM ... Once connected the unit will start to Scroll CCC … Showing connection is present ... Set Protocol for Xmodem, click send. ... Restart Hyper terminal session using the following port settings and check the control console for the proper AOS/Application files.
ap9620 Legacy Communications Card (LCC) Compatibility
For Smart-UPS units with the prefix ... Windows Operating System embedded UPS support ... Micro-link units . Refer to for details on supported ... An operating system no longer supported ... ... Includes all variations for voltage configuration and ... SURTD split phase models are ... 1 . Connect the ... Configure communications for 2400 baud ( ... second), 8 data bits, no parity, 1 stop bit, ... ... latest firmware version for your UPS. ... the attached document for the expected functionality ... LCC with each unit mentioned above. For the most up ... ... ) with any other SmartUPS models EXCEPT for ...
APC UPS Network Management Card (NMC) Compatibility Chart
... has been created for reference. ... cards, support for new device features ... Network Management Card for your device. ... application file, for use with the ... Firmware files for use in other UPS systems can be found ... Single and Three Phase ... Single phase Symmetra models ... ... -In- One Single and Three Phase ... Single phase Symmetra models ... ... -In- One * ... Phase Galaxy UPS units ... -installed in units manufactured post 2012 ... ... -in- One * ... 100/160 kW * Single Phase UPS models ... ... on MGE Galaxy units
ACRP1XX, ACRD5XX, ACRP5XX, and ACRC5XX Parts List
... list of parts for a ACRP1XX, ... ... 0521 ADPTR ELBOW 1 /2 INCH ... MM PEX ( FOR PIPING - Compression ... ... METRIC (adapter for connecting to metric ... ... 61194 ADPTR STRAIGHT 1 /2 INCH - 1 /2 INCH ... ... 0991 ADPTR STRAIGHT 1 /2 INCH ... ... CABLE ATS # 1 200-240v ... CABLE ATS # 1 480v 0w3122 CABLE ... ... ASSY Humidity Sensor For ACRP 1. ... ... ASSY Humidity Sensor For ACRP 17ft - ... ... /PROBE EMU 8 FT - SPARE ... /PROBE EMU 8 FT ASSY ( ... ... To Safety Plug for ACRPxxx (CW ...
DAC, Cancoil Installation Manual
Section 1 . Warranty and ... ... Air Cooled Condensers For information pertaining to ... Section 1 . ... year round operation for low, medium ... ... are conveniently located for ease of adjustment ... ... up are required for maximum benefit. Make arrangements for an inspector from ... ... provided in the unit . DO ... SECTION OF THE UNIT . Unit Placement and Mounting ... ... the condenser section for proper airflow. ... quipment is located indoors . unit should be securely ... ... clearance around the unit for proper servicing and ... For future reference, ... ... or equivalent alloy for brazing. ... , purge the system with dry nitrogen ...
What are the pinouts for the Output Relay on the Environmental Monitoring Unit (AP9319) and the Environmental Management System (ap9320)?
1 ... 8 ... 1 A, 30v AC/DC Since the user interface allows for either 'normally open' or 'normally closed,' APC recommends using only the normally open contacts and configuring the 'normal' state in the user interface.