Технические часто задаваемые вопросы



EcoAisle versus HACS
Resolution: • Active Flow Control - Right sizes cooling airflow while providing visibility to effective cooling to critical IT equipment.
Cannot log into PowerChute Business Edition 9.5 or 10 Agent web interface when user name is greater than 20 characters in length.
FAQ fa290624 2 - Stop PowerChute Agent Service See for assistance with starting and stopping Agent Service .
What are the basic troubleshooting steps for the APC AV H-Type power Conditioner ?
Input power cord is not connected properly Ensure supplied power cord is connected firmly at both ends.
What are the basic troubleshooting steps for the APC AV J-Type J25B / J35B Power Conditioner and Battery Backup?
Input power cord is not connected properly Ensure supplied power cord is connected firmly at both ends. The internal battery is not connected.
BMS AP9921X-AP9922 Battery Management System; high battery voltages on 40 Jar battery applications
... battery voltages on 40 Jar battery applications ... installed on a 40 Jar battery applications ... installed on a 40 Jar battery solution ... such as we see on MGE UPS ... it’s possible to see high voltages on ... ... the BMS power supply . First check the BMS “ ... the last battery 40 negative terminal. ... this is a 40 jar battery string ... at Battery jar 40 negative terminal. Please find wiring example below for 40 Jar battery string: ... Connector B - Wire 8 = Positive Terminal Battery 40 Connector B - Wire 9 = Negative Terminal Battery 40 Connector A - Wire 35 = Negative Terminal Battery 40
AOS v6.3.2/sy3p APP v6.3.2 UPS Network Management Card 2 (NMC2) ap9630/AP9631 UPS Compatibility
... including 20, 40 , 48, ... ... .2 will provide support for Symmetra PX 20, 40 , 80 kVA ... ... PX 20, 40 , and 80kva ... ... July 2015, provides support for Symmetra ... kVA models while maintaining support for Symmetra PX 20/ 40 /80. See below for a compatibility chart. ... Symmetra PX - (20/ 40 /80kva) supported with ap9630/31 ... Symmetra PX - (20/ 40 /80 kVA) supported with ap9630/31
Configuring PowerChute Business Edition versions 10.0 and above for use with the Windows SNMP Agent
NOTE: PowerChute Business Edition versions 9.2.1 and below use the Windows SNMP service , see
Smart Surge Protector is not connecting to the Wi-fi
Ensure you provide the correct Wi-Fi password for your home network when prompted.
What are the basic troubleshooting steps for the Smart-UPS SRT3KXLT / SRT3KRMXLT ?
The UPS display interface screen shows very low or no mains power. Check the mains power supply to verify acceptable power quality.
What are the basic troubleshooting steps for the Smart-UPS SRT5KXLT / SRT5KRMXLT / SRT6KXLT / SRT6KRMXLT ?
The UPS display interface screen shows very low or no mains power. Check the mains power supply to verify acceptable power quality.