APC Schneider Cooling Unit Identification
... Economizer BA= 208 - 230 /3/ ... BA= 208 - 230 /3/ ... AA= 208 / 208 /3/ ... ... =480/ 208 /3/ ... ... =600/ 208 /3/ ... AA= 208 / 208 /3/ ... ... =480/ 208 /3/ ... ... =600/ 208 /3/ ... AA= 208 / 208 /3/ ... ... =480/ 208 /3/ ... ... =600/ 208 /3/ ... ... Cooled BA= 208 - 230 /3/ ... 27 ( 8 T)
ACSC1XX Spare Parts List
... SC, ROTARY 208 - 230 /1/ ... ... COMP, ROTARY 208 - 230 /1/ ... ... fittings) . 13 "X. 13 "X. 13 " ... , 3/ 8 " ODF ( ... ... FITTING 1/ 8 " BARB 10 ... ... FITTING 1/ 8 " BARB TEE ... ... DRIER 3/ 8 "ODF SOLDER ... X 1/ 8 "GW ( ... RELAY DPDT 120vac 8 A PC MOUNT ... TXV VALVE 3/ 8 "ODM X 5/ 8 " ODF r410a 1.5 TON
ACRP1XX, ACRD5XX, ACRP5XX, and ACRC5XX Parts List
... /PROBE EMU 13 FT (RACK ... ... /PROBE EMU 8 FT - SPARE ... /PROBE EMU 8 FT ASSY ( ... ... Cable Main Power 208 /400v For ... 208 ... Breaker 3P 8 A 480v ... SHUTOFF 3/ 8 BSPT [PART ... SHUTOFF 3/ 8 BSPT [PART ... - 3/ 8 INCH [PART ... ... DRIER 5/ 8 " ODF SOLDER ... ... KG/H 208 VAC 3- ... ... PCB 811 CRAC 8 X OPTO SIMM ... ... -3/ 8 MPTX1/2 ... ... SHUTOFF 3/ 8 BSPT (Condensate ... MALE 3/ 8 OD 1/ ...
Spare parts list for ACRD1XX, and ACRD2XX
w0p2570 CRAC 8 X 2 FORM ... ... 2 POLE 30a 208 -240v - ... 208 - 230 /1/ ... 3/ 8 " ODF - SPARE PART 0.607 160.0 160.0 160.0 0.446 160.0 163.0 150.0 W875-00108 COIL SOLENOID VALVE 1/2" 208 ... 1/2"ODM X 5/ 8 " ODF EXTENDED, r410a 3 TON - SPARE PART 0.656 160.0 160.0 160.0 0.561 160.0 110.0 85
Symmetra LX Spare Parts List
Spare parts for 208 /240 VAC Symmetra LX systems (Symmetra system part numbers ending in "P" or "PXR") ... Symmetra LX 13 U replacement door - SYAFSU2 ... Symmetra LX 13 U left side panel - SYAFSU9L ... Symmetra LX 13 U right side panel - SYAFSU9R ... For 220/ 230 /240/380/400/415 VAC Symmetra LX systems (Symmetra system part numbers ending in "I" or "IXR") ... Symmetra LX 13 U replacement door - SYAFSU2 ... Symmetra LX 13 U left side panel - SYAFSU9L ... Symmetra LX 13 U right side panel - SYAFSU9R
Video: How do I upgrade the firmware on an APC Network Management Card (NMC) or NMC embedded device (Rack PDU, etc)?
... /AP9617/ 8 /9 installed 8 . Wait for ... ... no parity, 8 data bits, ... 8 . Select option ... 13 . ... 57600 bps, 8 data bits, ... 8 . Type reset ... 3. Run a terminal program such as HyperTerminal, and configure the selected port for 57600 bps, 8 data bits, no parity, 1 stop bit, and no flow control. ... 230 User logged in, proceed. ... 8 . Repeat Steps 3 - 8 again for the application module (sumx for Smart UPS/Matrix, sy for Symmetra, etc).
I need a wiring diagram for the outdoor receiver heaters.
If the unit is 208 / 230 the incoming power can be split and the heater can be wired direct with fuses to protect the ...
Use of 208v Smart-UPS products in 240v environments
Because of this they can input or output 208 , 220, 230 , or 240v and are perfect for customers wanting to deploy a ...
Changing the Line VRMS (Nominal Line Voltage) on your 208/230vac capable Rack Automatic Transfer Switch (ATS)
Go to 1-Device Manager menu, 3-ATS Configuration and configure item 8 -Line VRMS to 208 Important: