Consultar las preguntas frecuentes



Spare parts list for ACRD1XX, and ACRD2XX
... 380.0 5 .450 69.0 1 ,917. ... ... 330.0 1 .956 50 ... DP 2 POLE 30a 208 -240v - ... 208 -230/ 1 /60, ... 31.900 480 .0 290 ... ... COIL SOLENOID VALVE 1 /2" 208 1 /2" ... ... -240/ 1 /50, ... 32.140 480 .0 290 ... 1 /2" ... 1 /2"ODM X 5 /8" ... ... .0 332.0 2.013 130.0 72 .0 275.0
Where can I get support for APC and MGE Products?
... 6 0034- 1 0034-100 ... 2M- 1 E 0035nd-3M- 1 E 0039- ... ... 2M- 1 E 0088nd-3M- 1 E 0100- ... 2M- 1 E 0226- ... 3 0377- 1 M 0377- ... ... 2M- 1 E 0719- ... 7 0859- 1 0859-10 ... ... 15M 12000- 1 M 12000- ... M 12000- 5 M 12008- ... 15M 12008- 1 M 12008- ... M 12008- 5 M 12012-15M 12012- 1 M-E ...
How to take the Single Galaxy 5000 UPS from normal operation to total power off using an external Maintenance Bypass Panel
... to take the Single Galaxy 5000 UPS ... This procedure is for a single UPS with an external maintenance bypass panel. ... Step 1 : Touch any button on the display to wake it up. ... Step 5 : Press the Inverter OFF (gray) button for 3 seconds to transfer the load to the Static Bypass Switch. ... Step 6: In the MBP (Maintenance Bypass Panel), push and hold the “Transfer Initiate” button. ... Turn off the CB2 Isolation Breaker. ... Turn off Q 1 Switch
88 volts from the North American Symmetra Power Array output block
88 volts is measured between ... The design of the isolation transformer in the North American Symmetra Power Array allows multiple output voltages to be derived. The output terminal block provides two 120 volt legs and one 88 volt leg. Once the needed output voltage is determined it is imperative to validate the appropriate legs to take to the panel to generate the needed output voltage . The 88 Volt leg is used with the 120 volt leg to derive 208 volts as needed for 208 volt loads. ... Tap 2 generates 120 Volts Tap 4 generates 88 volts Tap 6 generates 120 Volts
APC Schneider Cooling Unit Identification
Voltage ... Economizer BA= 208 -230/ ... KA= 480 /3/ ... Voltage BA= 208 -230/ ... KA= 480 /3/ ... AA= 208 / 208 /3/ ... CA= 480 / 208 /3/ ... DA= 480 / 480 /3/ ... ... =600/ 208 /3/ ... Voltage AA= 208 / 208 /3/ ... CA= 480 / 208 /3/ ... DA= 480 / 480 /3/ ... ... =600/ 208 /3/ ... Voltage AA= 208 / 208 /3/ ...
Single Phase Symmetra Drops the Load When Returning from Bypass
Input Voltage: Line I 132.7, Line II 132.7, LI-LII 230 VAC Output Voltage Setting: 208 V
Symmetra Power Array reads "Bypass Out of Range"
If the tenth bit is equal to " 1 ", then the Input voltage Jumper is set at the 208 volt position.
ACRP1XX, ACRD5XX, ACRP5XX, and ACRC5XX Parts List
... 0521 ADPTR ELBOW 1 /2 INCH ... ... 61194 ADPTR STRAIGHT 1 /2 INCH - 1 /2 INCH ... ... 0991 ADPTR STRAIGHT 1 /2 INCH ... ... CABLE ATS # 1 200-240v ... CABLE ATS # 1 480v 0w3122 CABLE ... ... p30a to P 5 & P6 ... p30a to P 5 & P6 ... Cable Main Power 208 /400v For ... 208 ... Breaker 2P 5 A 240v ... Breaker 2P 5 A 480v ... Breaker 3P 5 A 240v ... Breaker 3P 5 A 480v ... HEATER ASSY # 1 w0m-9895 ELBOW ADPTR REDUCTION 1 /2 INCH ...
Batteries discharged to a low voltage in a single phase Symmetra frame
... Symmetra is powered down for more than 72 hours with the batteries left installed in the frame, they will discharge to a voltage at ...
Changing the Line VRMS (Nominal Line Voltage) on your 208/230vac capable Rack Automatic Transfer Switch (ATS)
Go to 1 -Device Manager menu, 3-ATS Configuration and configure item 8-Line VRMS to 208 Important: