ACRP1XX, ACRD5XX, ACRP5XX, and ACRC5XX Parts List
All Serial Numbers. ... 0521 ADPTR ELBOW 1 /2 INCH ... ... 61194 ADPTR STRAIGHT 1 /2 INCH - 1 /2 INCH ... ... 0991 ADPTR STRAIGHT 1 /2 INCH ... ... CONTROL - acrp5xx 208v (CW ... CABLE ATS # 1 200-240v ... CABLE ATS # 1 480v 0w3122 CABLE ... ... the fan grill module ] ... - acrp1xx ( DX ... (CW AND DX ... FAN acrp1xx ( DX ) ... Reheat acrp1xx ( DX ) ... for acrp1xx ( DX ) ... /102 ( DX ) ... For acrp101 ( DX ) ... for acrp100 ( DX ) ... for acrp101 ( DX ) ) 208v
ACSC1XX Spare Parts List
All serial numbers. 1 1 1 1 1 ... -230/ 1 /60 ( ... ... -240/ 1 /50 ( ... ... -230/ 1 /60, ... 1 ... -240/ 1 /50 SC ... 1 ... voltage 120v/ 208v ) 1 1 1 1 1 EVAPORATOR FAN MODULE ASSY - 17 ... 1 ... WASHABLE IR SERIES 1 /2" ... FITTING 1 /8" ... FITTING 1 /8" ... 1 ... BULKHEAD MOUNT ( single float) 1 ... 1 ... 1 GROMMET RUBBER 1 1 /2"ID X 1 3/4"GD X 1 /8"GW (for power cable at the bottom) ... 1 ... InRow RC/SC Filter 1 /2" Washable - Spare Part (default)
APC Schneider Cooling Unit Identification
All Cooling Units. All Product models, all serial numbers. Module Module Module Module AFX 1 = 1 Bay ... Bay 06 ( 1 Bay) 08 ( 1 Bay) ... CM 003 ( 1 T) ... -230/ 1 /60 ... =277/ 1 /60 1 -5T ... 1 -3T ... ... -230/ 1 /60 ... =277/ 1 /60 ... CM 15 ( 1 T) ... =208/ 1 /60 ... =230/ 1 /60 ... =277/ 1 /60 ... Drycooler 15 ( 1 T)
Can you interconnect A-Links CW and DX InRow Cooling products?
... acrp10x, acrp50x, acrd50x and acrc50x can all be grouped with "like" units (CW to CW, DX to DX ) ...
What is the input voltage required for the InRow acrd100/200? Is a power cord supplied with the unit?
All versions. ... The InRow RD unit uses a single phase 208v /60hz input in NAM and a 230v/50hz input in the rest of the world.
What are the Condensate Pump lift specifications for your InRow product line?
What are the Condensate Pump lift specifications for your InRow product line? ... All InRow Units ... All of the InRow products come with a factory-installed condensate pump piped internally to the condensate pan. ... InRow acsc100, acsc101, acrd100, acrd200, acrc100, acrc103 ... InRow SC, RD (300mm): ... One float is used for condensate pump control, the other to generate condensate pan overflow alarms. ... x = denotes the voltage is for 208v or 460v
Bypass settings of Single Phase Symmetra UPS systems
What are the different bypass settings of a single phase Symmetra UPS? ... All serial ranges ... These Symmetra UPS systems are designed to operate off of a nominal input voltage of 208v or 240v. ... When the input voltage is within this range the power modules are capable of producing a steady output voltage. ... When the UPS is overloaded, or there is a fault that prevents the Power Modules from powering the load normally, the UPS will consider powering the load via Bypass.
Single Phase Symmetra Drops the Load When Returning from Bypass
A single phase Symmetra UPS ... All serial numbers ... load equipment in all modes of operation ... ... voltage setting on single phase Symmetra systems ... ... bypass setting on single phase Symmetra UPS ... If the input voltage goes outside of this range, the system will indicate "Bypass Out of Range" and will drop the load if power module output happens to collapse (such as in the event of an overload). ... If the UPS is overloaded or the Power Modules are unable to normally power the load, the UPS will drop the load. ... Output Voltage Setting: 208v
"Site Wiring Fault" message on Symmetra LX UPS Systems
All serial ranges ... The Symmetra LX UPS split-phase UPS system is designed to operate off nominal input voltages of either 208v or 240v consisting of 4 Wires: 2 phases, a neutral and ground. ... 1 .) If the UPS does not detect a good neutral connection, it will report a Site Wiring Fault if the Intelligence Module master firmware revision is 512 or greater. The SYPM4KP Power Modules , regardless of firmware revision, will rapidly click until the Neutral connection is corrected.
How to change the Input Voltage Select Jumper on a Symmetra Power Array
All serial numbers ... 1 . Switch the System Enable switch to the OFF position. ... 4. Remove all battery modules from the UPS. ... 1 . Refer to figure below. ... In the 208v position, the micro switch is not activated.