Our Brands

APC Smart-UPS RT 15kVA, 230/400V, LCD, rackmount, 12U, 2x IEC Jumpers & 8x IEC 60320 C19 outlets

SURT15KRMXLI

notification_ok
notification_ok
Environmental performance of the product Learn more
Sustainable by Design
Energy Efficient
Take-back
Transparency
RoHS/REACh
Energy Efficient
Take-back
Transparency
RoHS/REACh
Online stores
arrow2_down

+ Lifecycle Services

arrow2_down

Specifications

Overview
PresentationHigh density, double-conversion on-line power protection with scalable runtime.
Lead timeUsually in Stock
Main
Run time for load
W
information_circle
Enter the total load (power draw) of all devices that will be protected by the UPS. This will be used to estimate the run time of your devices during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down.
Min-max: 1200-12000 W
Max. Capacity Used
information_circle
The maximum percentage of UPS capacity used to support your specified load.
Main Input Voltage230 V
400 V 3 phases
Other Input Voltage220 V
240 V
Main Output Voltage230 V
Other Output Voltage220 V
240 V
Rated power in W12000 W
Rated power in VA15000 VA
output connection type2 IEC Jumpers
8 IEC 60320 C19
output connector typeHard wire 3-wire (H N + E) 1
Hard wire 5-wire (3P + N + E) 1
number of rack unit12U
battery typeLead-acid battery
provided equipmentCD with software
Rack mounting support rails
Smart UPS signalling RS-232 cable
User manual
Web/SNMP management card
General
Number of power module free slots0
Number of power module filled slots0
RedundantNo
Physical
colourBlack
Height53.3 cm
width43.2 cm
Depth77.3 cm
Net weight247.73 kg
mounting locationFront
mounting preferenceLower
mounting modeRack-mounted
Two post mountable0
USB compatibleNo
Input
network frequency40...70 Hz auto-sensing
number of input connectors1 hard wire 3-wire (1P + N + E)
1 hard wire 5-wire (3P + N + E)
input voltage limits160...280 V
maximum input current90 A
Switching current capacity100 A
input harmonic distortionLess than 5 % for full load
input current90 A (1 phase)
30 A per phase (3 phases)
load power factor0.8
Input Power Factor at Full Load0.95
Output
Maximum configurable power in W12000 W
Harmonic distortionLess than 5 %
output frequency50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz sync to mains
crest factor3 : 1
UPS typeDouble conversion online
Wave typeSine wave
output overload operation60 seconds at 125% and 30 seconds at 150%
bypass typeBuilt-in static bypass
Internal bypass (automatic and manual)
Optional external bypass
efficiency93 % (in battery operation)
Maximum configurable power in VA15000 VA
Conformance
product certificationsVDE
standardsEN/IEC 62040-1:2019/A11:2021
EN/IEC 62040-2:2006/AC:2006
EN/IEC 62040-2:2018
Environmental
Ambient air temperature for operation0…40 °C
relative humidity0…95 % non-condensing
Operating altitude0...10000 ft
Ambient air temperature for storage-15…45 °C
storage Relative Humidity0…95 % Non-condensing
Storage altitude0.00…15240.00 m
Acoustic level50 dBA
Heat dissipation2800 Btu/h
IP degree of protectionIP20
Batteries & Runtime
Run TimeView Runtime Graphaction_new_window
EfficiencyView Efficiency Graphaction_new_window
number of battery filled slots4
Number of battery free slots0
Battery recharge time2.5 h
number of battery replacement quantity4
Additional informationConfigurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Battery voltage+/- 192 V (split battery referenced to neutral)
battery charger power1530 W rated
Battery power in VAH3840 VAh runtime
Battery life3…5 year(s)
Replacement batteryAPCRBC140action_new_window
battery optionSURT192RMXLBP2 1 7680 VAh
SURT192RMXLBP2 2 11520 VAh
SURT192RMXLBP2 3 15360 VAh
SURT192RMXLBP2 4 19200 VAh
SURT192RMXLBP2 5 23040 VAh
SURT192RMXLBP2 6 26880 VAh
SURT192RMXLBP2 7 30720 VAh
SURT192RMXLBP2 9 38400 VAh
extended runtime1
Communications & Management
Free slots0
preinstalled deviceNetwork management card 2 with environmental monitoring
control panelMultifunction LCD status and control console
alarmAudible and visible alarms : configurable delays
Emergency power offYes
Surge Protection and Filtering
noise suppressionFull time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height99 cm
Package 1 Width61 cm
Package 1 Length100.3 cm
Package 1 Weight314.09 kg
Unit Type of Package 2PAL
Number of Units in Package 22
Package 2 Height112 cm
Package 2 Width100 cm
Package 2 Length120 cm
Package 2 Weight626.864 kg
Contractual warranty
Warranty2 years repair or replace
arrow2_down

Sustainability

Green premium brand logo
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn morearrow2_left
Resource performance

Energy efficient product

notification_ok

Take-back program available

notification_ok
Well-being performance

Mercury free

notification_ok

RoHS exemption information

REACh Regulation

EU RoHS Directive

Environmental Disclosure

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Circularity Profile

arrow2_down

Documents

arrow2_down

Software and Firmware

Need more information? Check our technical FAQs!

Easily find answers to the most frequently asked questions.