What is the maximum number of XR frames allowed with a Symmetra PX 20, 40 and 80kw solution?
This would make for a total of 4 battery frames in addition to the Main UPS frame which houses the Power Modules.
Symmetra PX1-PX2; What happens when PX1, PX2 and 250/500k PX is EPO'd
... 250/500k PX is EPO'd Symmetra PX ... describes how the Symmetra PX reacts to the ... PX : ... circuit in the Symmetra PX is activated the ... in the Main Frame or in the XR Frame (80kw units ... ... tripped on ISX PDU . There is no power on the output of the XR Battery Frames or on the output of the Symmetra PX UPS . ... PX : ... Only the Battery CBs on XR frames will be tripped. Customer would need to have optional shut trip on Upstream CB to turn off input power to UPS . ... PX : ... Reset EPO switch and follow proper procedures to restart UPS
Symmetra PX2; Why are the NMC Data Logs Blank?
Symmetra PX2, sycf100kf ... ... settings in the UPS Display. ... You might get UPS faults about lost ... PDU NAM Used when; PX2 100kw PDU products are present PDU NDF Used when; Dual Mains PX2 100kw PDU products are present PDU / XR Used when; All in one (AIO) Frame such as the PX48 ... Used when non-modular PDU is present, such as PDPMQ (with 0M-5103 Brain CAN) OR a modular PDU that has no modular breakers installed ... Used when; no PDU or MBP is present
Where can I get support for APC and MGE Products?
Basic Rack PDU ... Charge- UPS EX ... Matrix- UPS Matrix- UPS Accessories Metered Rack PDU Metered-by-Outlet Rack PDU ... MGE UPS 4000 ... NetShelter Open Frame Rack Accessories ... Open Frame Racks ... Rack PDU Accessories ... Smart- UPS Smart- UPS Accessories Smart- UPS Battery Systems Smart- UPS DP Smart- UPS On-Line Smart- UPS RT Smart- UPS VT ... Start -Up Service ... Switched Rack PDU Symmetra Symmetra Accessories Symmetra Battery Systems Symmetra MW Symmetra MW Accessories Symmetra Power Module Symmetra PX Symmetra PX Accessories ... Tune- UPS for Symmetra ... UPS Network Hub Card UPS Network Management Cards
Input Circuit Breaker Requirements for Symmetra PX 20/40/80 kw
This document describes the required input over current protection (circuit breaker) required when installing a Symmetra PX ... Symmetra PX1 Products ... Input Circuit Breaker Requirements for Symmetra PX 20/40/ 80 kw ... Symmetra PX 40 ... 80a 480vac ( PDU w/ Step Down Transformer required) 60a 600vac ( PDU w/ Step Down Transformer required) Symmetra PX 80 ... 150a 480vac ( PDU w/ Step Down Transformer required) 125A 600vac ( PDU w/ Step Down Transformer required) ... (APC Symmetra PX Frame Installation Deviation and Selection of Input Circuit Breaker Ratings)
How do I replace a single phase Symmetra battery module?
Remove the front cover of the UPS or XR frame and locate the faulty battery module(s).
Single Phase Symmetra XR Frame Compatibility
Symmetra RM UPS : SYRMXR4B4.
How can I extend the cable length of a Symmetra LX or Symmetra RM XR battery frame?
The need may arise for there to be space between the UPS mainframe and XR frames i.e. if they cannot be installed ...
Where do I get information on MPRS – Modular UPS Revitalization Service for Symmetra PX products
... /en/products/Modular- UPS -Revitalization-Service-for-1- Symmetra - PX -80k- Frame - ...
Symmetra XR frame displaying an invalid address such as 10 or 11
Environment Any UPS in the product families listed above with an extended run ( XR ) frame attached.