Browse FAQs



What type of battery could I use with the Galaxy VS UPS?
Galaxy VS, 3 Phase UPS , Uninterrupted Power Supply, 10 kVA , 15 kVA ,20 kVA , 20 kVA ,30 kVA ,40kva, ... use with the Galaxy VS UPS ?, battery ...
Video: How can the Galaxy VS reduce my energy bill?
Galaxy VS, 3 Phase UPS , Uninterrupted Power Supply, 10 kVA , 15 kVA ,20 kVA , 20 kVA ,30 kVA ,40kva, ...
Galaxy 3500, Smart-UPS VT and ais3000 Power Factor Information
Galaxy 3500 , Smart- UPS VT and ais3000 Power Factor Information ... Galaxy 3500 , Smart- UPS VT and ais3000 ... Galaxy 3500 , Smart- UPS VT and ais3000 Power Factor Information ... "The SUVT and the ais3000 have an Input Power Factor Correction Module which corrects the Power Factor on the input of the unit. The Input Power Factor is 1 .
Where do I find information on electrolyte contained within the SYBTU1-PLP and SYBTU2-PLP type APC modular batteries
... 80 and 96KVA UPS units as well as the SUVT and Galaxy 3500 UPS units) and ... 250/500kva UPS units) batteries.
Which SmartSlot accessories are supported by the Galaxy 3500 (g3500) UPS?
... supported by the Galaxy 3500 (g3500) UPS ? ... Facility 3 Phase UPS MGE Galaxy 3500 models ... supported by the Galaxy 3500 UPS (g3500) ... ... with the g3500 UPS . ... with the g3500 UPS . ... inputs, ( 1 ) output per ... ... in the g3500 UPS . ... in the g3500 UPS . ... front panel/ UPS door will not ... 1 .) Purchase ... ... an APC ap9600 single slot SmartSlot expansion ... ... top of the UPS . ... SmartSlot in the UPS frame. ... comes with a 10 ' cable. ... communication cable can be routed so that the chassis can sit on top of the UPS .
How do I connect a EPO circuit to Smart-UPS VT or Galaxy 3500 Battery XR Frame?
Galaxy 3500 , SUVT , EPO, REPO, g3500, Battery frame, XR frame, XR frame EPO circuit wiring, Installation – ...
What UPS units are officially supported by the ap9610 (Relay I/O SmartSlot Card)?
SURTA SUVT / Galaxy 3500 (Must use Configuration #2 - same as Symmetra)
What UPS units are officially supported by the AP9613 (Dry Contact I/O SmartSlot Card)?
SURTD SUVT / Galaxy 3500 (Must use Configuration #2 - same as Symmetra)
Smart-UPS VT-g3500; Load does not turn on automatically after an outage/shutdown
Suvt autostart, Galaxy 3500 Autostart, SUVT turn load on, set auto start to on, restart, how to set auto start ...


Results 1 - 10 of 50

Can't find what you are looking for?

Reach out to our customer care team to receive information on technical support, assistance for complaints and more.