Browse FAQs



APC Schneider Cooling Unit Identification
APC Cooling Unit identification. All Cooling Units. ... W= Water Cooled ... F= Water Cooled ... D= Water Cooled ... G= Glycol Cooled ... B= Glycol Cooled ... P= Glycol Cooled ... =208- 230 / 3 / 60 ... = 480/ 3 / 60 ... = 600/ 3 / 60 E= Electric A= 3 row 20 ... coil C= Chilled Water ... =208- 230 / 3 / 60 ... = 480/ 3 / 60 ... = 600/ 3 / 60 ... /208/ 3 / 60 ... /208/ 3 / 60
What are the operational conditions for an InRoom (Stulz) Unit
... / 3ph / 60 Hz ... / 3ph / 60 Hz ... imbalance: < 3 % Frequency: 60 Hz +/- 1 % Chilled water-/ cooling water pipes: ... piping between the cooling unit and the ... cooled condenser: 60 m (200 ... ... condenser and the cooling unit: 5 ... is below the cooling unit ... condensing temperature: 60 °C ( ... Cooling fluid (DX) ... Fluid inlet temperature ( ... Fluid outlet temperature (G): 40°C (104°F) Chilled water medium (CW): 0% Glycol Data is valid for: 460v / 3ph / 60 Hz
Network Air FM unit spare parts list
ADAPTER ROTO 1 1 /4" ... ADAPTER ROTO 1 "-14R ... ... FLOW-RATER fm40 W/ CAP ... CKT BKR 3 P 20a 480vac ... CKT BKR 3 P K 16A ... CKT BKR 3 P K 20a ... CKT BRKR 3 P 100a 600v ... CKT BRKR 3 P 150a 600v ... CKT BRKR 3 P 25A 480v ... CKT BRKR 3 P 30a 600v ... CKT BRKR 3 P 40a 480v ... CKT BRKR 3 P 40a 600v ... CKT BRKR 3 P 50a 600v ... CKT BRKR 3 P 60a 480v ... CKT BRKR 3 P 70a 600v ... ... FIX SOLUTION # 3 ... - MKC- 1
How to navigate through an Network Air FM unit display
... MultiCool® ( chilled water) and ... ... , then the cooling setpoint is used ... ... NetworkAIR FM DX 60 Hz Up to three Modules can be ... work as a single System. ... Half capacity uses one compressor and half ... ... avoid over- cooling while dehumidifying. ... valve which feeds three quarters of the ... ... the modes ( cooling , reheat, ... The condenser fluid valve close delay ... ... , the condenser fluid valve closes. ... compressor (stage 1 ) in a ... ... NetworkAIR FM DX 60 Hz Installation Settings for fluid - cooled options ... each type of fluid - cooled option.
Information on Online and On Battery operation of 3:1 Symmetra UPS systems
The output voltage can be set to either 220 / 230 / 240 VAC at 50 or 60 Hertz.
How to properly set FM condenser set points
Data Center Cooling ... 1 ×N or 2×N ... S 1 ºC (°F) ... OFFSET S 3 ... LNH-s02-a017 1 x 1 1 x 2 1 x 2 x ... x fm40 LNH-s02-a011 ... LNH-s02-a026 1 x 2 1 x 2 1 x 3 87 ... LNH-s02-a026 1 x 2 1 x 2 1 x 3 77
What are the factors that affect Battery Rated Service Life?
1 )Design Life ... 3 )Duty Cycle ... Maintenance of fluid levels, terminal torques. ... If one looks at these terms, and considers them with the simplest explanation, it is easy to see that Design Life is the life expectancy the manufacturer says the battery is capable of, provided that all of the specification parameters are maintained. ... APC_WHITE_PAPER 230 : Lead Acid Battery Lifecycle
ACRP1XX, ACRD5XX, ACRP5XX, and ACRC5XX Parts List
... 0521 ADPTR ELBOW 1 /2 INCH ... ... 0989 ADPTR PIPE 3 " ENGL TO ... ... 61194 ADPTR STRAIGHT 1 /2 INCH - 1 /2 INCH ... ... 0991 ADPTR STRAIGHT 1 /2 INCH ... , GAS SHUTOFF 3 /4" ... ... CABLE ATS # 1 200-240v ... CABLE ATS # 1 480v 0w3122 CABLE ... VAC 3 Phase - Spare ... VAC 3 Phase - Spare ... ... r0357 Circuit Breaker 3 P 10a 280v ... r0457 Circuit Breaker 3 P 10a 480v ... r0427 Circuit Breaker 3 P 15A 480v ... r0457 Circuit Breaker 3 P 20a 240v ... r0487 Circuit Breaker 3 P 30a 240v
Spare parts list for ACRD1XX, and ACRD2XX
... 69.0 1 ,917. ... ... 330.0 1 .956 50 ... UNION 3 /4" ... 208- 230 / 1 / 60 , 10kw, ... 3 /8" ... COIL SOLENOID VALVE 1 /2" ... 3 /4" ... 1 /2" ... ... -240/ 1 /50, ... 1 /2" ... 1 /2"ODM X 5/8" ODF EXTENDED, r410a 3 TON - SPARE PART 0.656 160.0 160.0 160.0 0.561 160.0 110.0 85
Smart-UPS fan operation parameters
1 . The UPS ... 3 . The UPS has a load greater than 75% ... ... UPS has reached greater than 140 degrees F ( 60 degrees C) ... ... have to be greater than 104 degrees ... On these units the fan will always be on in low speed mode, and will switch to high speed mode should one of the following events occur: 1 . The UPS is on battery. ... 3 . The UPS has a load greater than 75%. 4. The internal temperature of the UPS has reached greater than 104 degrees F (40 degrees C).


Results 1 - 10 of 50