Configuration and use of the surt003 and SRT5KTF Transformers
Resolution: L 6-20r (qty2) - 208v (120v Hot, 88v Hot, Ground) L6-30r (qty1) - 208v (120v Hot, 88v Hot, Ground)
Verification of Matrix-UPS input voltage configuration
menu will reflect the actual output voltage from either the L6-30r or the L14- 30r . If UPS FW rev
What are the standard output receptacles for the Matrix UPS line?
The Matrix comes standard with ( 6 ) 5-15 receptacles, ( 2 ) L 6 -30 receptacles and ( 1 ) ...
Phase Sources on Symmetra LX PDU Panel SYAPD1
... not overload any one phase? ... so could cause one of the phases ... ( 2 ) L 5- 20r (3-pin twist-lock) ( 1 ) L14- 30r (4-pin twist-lock) ... The L 5- 20r outlets provide single -phase 100, 110, or 120v AC (Phase-Neutral) service. ... The L 5- 20r located on the left of the SYAPD1 PDU Panel sources from Phase 1 . The L 5- 20r located on the right of the SYAPD1 PDU Panel sources from Phase 2 .
Where can I get support for APC and MGE Products?
... 10 0031- 6 0033-10 ... 50 0033- 6 0034- 1 0034-100 ... 100 0035- 2 M-E ... E 0035nd- 2 M- 1 E 0035nd-3M- 1 E 0039- ... ... 25 0088- 2 M-E ... 50 0088nd- 2 M- 1 E 0088nd-3M- 1 E 0100-6RA 0129- 2 M-E 0129nd- 2 M- 1 E 0226- ... 3 0377- 1 M 0377- 2 M 0377- ... ... 3 0423- 6 0429-25 ...
Description of NEMA L6-30 Receptacle
The NEMA L 6 -30 is ... models, and Symmetra RM 2 -6kva UPS. The NEMA L 6 -30 receptacle is also used as an output receptacle for supplying 208 VAC in the Matrix-UPS, the Smart-UPS T models, and single phase Symmetra systems (Power Array, RM, LX). It is a locking two -pole, three-wire grounding receptacle with a maximum input of 250v and 30a. ... X= L 1 (Hot) Y= L 2 (Hot)
Mass Configuration of Users and User Preferences on Network Management Card 2 (NMC2) v6.X.X
... Network Management Card 2 - ap9630/ ... ... Network Management Card 2 include (but ... to): 2 G Metered/ ... v 6 .X. ... ... Network Management Card 2 (NMC2) ... The .csf file must only contain one command per line. ... [- l (shows current user list)] ... and you'll be able to upload it to your NMC2 via one of the specified methods. To confirm your changes were accepted, you can display the current user list by issuing the command user - l
How do I replace a single phase Symmetra power module?
... module in a single phase Symmetra UPS ... ... modules in a single phase Symmetra UPS ... 1 .) Remove ... ... their location ( L 1 - L 5). ... bays are labeled L 1 - L 5 (from ... 2 .) Install ... Symmetra RM 2 - 6 kva 1 .) Remove ... ... their location ( L 1 - L 4). ... bays are labeled L 1 - L 4 (from ... Loosen the two thumb screws in ... 2 .) Install ... 1 .) Remove ... ... their location ( L 1 - L 4).


Results 1 - 10 of 50

Can't find what you are looking for?