APC Schneider Cooling Unit Identification
M= Main C= Chilled Water BA= 208 - 230 / 3 / 60
What are the operational conditions for an InRoom (Stulz) Unit
... / 3ph / 60 Hz 208 -230v / 3ph / 60 Hz ... imbalance: < 3 % Frequency: 60 Hz +/ ... Chilled water -/ cooling water pipes: Maximum water head pressure: ... ... piping between the cooling unit and the ... cooled condenser: 60 m (200 ... ... condenser and the cooling unit: 5 ... is below the cooling unit Entering water temperature (EWT ... Leaving water temperature (LWT ... ... condensing temperature: 60 °C ( ... Cooling fluid (DX ... Chilled water medium (CW ... ... / 3ph / 60 Hz Downflow units with an external static pressure: 20 Pa (0.08 in w g)
ACSC1XX Spare Parts List
... SC, ROTARY 208 - 230 /1/ 60 (Toshiba conversion ... ... COMP, ROTARY 208 - 230 /1/ 60 , SC, ... ... activation without the water sensor kit) 3 ... 3 ... ELECTRONIC EXPANSION VALVE, 3 /8" ODF (HGBP) ... 3 ... 3 ... FILTER-DRIER 3 /8"ODF SOLDER ... GROMMET RUBBER 1 1/2"ID X 1 3 /4"GD X 1/8"GW (for power cable at the bottom) ... 3 ... 3 ... TXV VALVE 3 /8"ODM X 5/8" ODF r410a 1.5 TON
Uniflair Humidifier Water Quality
Uniflair Humidifier Water Quality. Data Center Cooling . ... electrodes in the water generates the heat ... to boil the water and the amperometric ... ... closing the feed water solenoid valve and ... ... , the feed water solenoid valve is ... The cylinder electric drain valve is opened at intervals depending on the characteristics of the feed water supply in order to maintain the optimum concentration of dissolved minerals in the water in the cylinder. Feed water Values for the feed water for medium-high level of conductibility of a humidifier with immersed electrodes: ... ) 100 Temporary hardness mg/l 60 ( 3 ... ( 3
Spare parts list for ACRD1XX, and ACRD2XX
... 2 POLE 30a 208 -240v - ... UNION 3 /4" ... 208 - 230 /1/ 60 , 10kw, ... 3 /8" ... /2" 208 3 /4" ... 1/2"ODM X 5/8" ODF EXTENDED, r410a 3 TON - SPARE PART 0.656 160.0 160.0 160.0 0.561 160.0 110.0 85
Uniflair Pump Packages Technical Specs
Data Center Cooling . ... Package 2 HP 208 -230v/ 3 / 60 Hz, FlowRate ... ... Package 2 HP 208 -230v/ 3 / 60 Hz, FlowRate ... ... Package 5 HP 208 -230v/ 3 / 60 Hz ... .5 HP 208 -230v/ 3 / 60 Hz ... HP 460v/ 3 / 60 Hz, FlowRate ... ACPP2325 Dual Pump Package 2 HP 460v/ 3 / 60 Hz, FlowRate 53 GPM ACPP2326 Dual Pump Package 5 HP 460v/ 3 / 60 Hz ACPP2327 Dual Pump Package 7.5 HP 460v/ 3 / 60 Hz
How to navigate through an Network Air FM unit display
... MultiCool® ( chilled water ) and DX ... ... , then the cooling setpoint is used ... ... NetworkAIR FM DX 60 Hz Up to three Modules can be ... Water ... avoid over- cooling while dehumidifying. ... valve which feeds three quarters of the ... ... the modes ( cooling , reheat, ... ... NetworkAIR FM DX 60 Hz Installation ... for fluid- cooled options ... of fluid- cooled option. ... (glycol or water ) flow to ... ... will switch the cool or dehumidify mode ... ... —for the water or glycol line ...
Are the fans in a 600mm Cooling unit single phase or 3-phase?
Resolution: 3 Phase either 208 -230vac, or 460vac
NetworkAIR FM 3-Way Valve Flow Pattern
600 WOG Body Rating Chilled or Hot Water , Glycol up to 50%
What is the IP (ingress or international protection) rating of SMC, SMT and SMX series Smart-UPS?
2 = Protects against dripping water of +- 15 degree angle 3 = Protects against spraying water of +- 60 degree angle