NetBotz Wireless Sensor Pod 180

Share:

NetBotz Wireless Sensor Pod 180

NBPD0180

Description: Wirelessly transmit sensor data to a NetBotz appliance.

Includes : Humidity sensor , Installation guide , Temperature Sensor , USB cable , Wall Mounting Brackets

In stock
$259.99

Related Products, Accessories & Services

View all accessories and replacement batteries for this product

NBPD0180Features

NetBotz Wireless Sensor Pod 180

Wirelessly transmit sensor data to a NetBotz appliance.

Includes : Humidity sensor , Installation guide , Temperature Sensor , USB cable , Wall Mounting Brackets

  • Battery replacement without tools
    Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
  • Humidity monitoring
    Changes in humidity are reported via the user interface or e-mail.
  • Temperature monitoring
    Changes in temperature are reported via the user interface or e-mail.

NetBotz SensorsFeatures & Benefits

  • Optional sensors
    Add sensors to compatible NetBotz Appliances for monitoring temperature, humidity, fluid, vibration, dust particles, etc.
  • Low profile sensors
    Small sensors allow for placement flexibility.
  • Unique identifiers
    Customize each sensor with a differentiating name and location.
Product Distribution
Product Distribution

Andorra , United Arab Emirates , Afghanistan , Antigua and Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Austria , Australia , Aruba , Azerbaijan , Bosnia and Herzegovina , Barbados , Bangladesh , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Bermuda , Brunei , Bolivia , Brazil , Bahamas , Bhutan , Botswana , Belarus , Belize , Canada , The Democratic Republic Of Congo , Central African Republic , Congo , Switzerland , Côte d'Ivoire , Cook Islands , Chile , Cameroon , China , Colombia , Costa Rica , Serbia and Montenegro , Cuba , Cyprus , Czech Republic , Germany , Djibouti , Denmark , Dominica , Dominican Republic , Algeria , Ecuador , Estonia , Egypt , Western Sahara , Eritrea , Spain , Ethiopia , Finland , Fiji , Falkland Islands , France , Gabon , United Kingdom , Grenada , Georgia , French Guiana , Ghana , Gibraltar , Gambia , Guinea , Guadeloupe , Equatorial Guinea , Greece , Guatemala , Guyana , Hong Kong , Honduras , Croatia , Haiti , Hungary , Indonesia , Ireland , Israel , India , Iraq , Iran , Iceland , Italy , Jamaica , Jordan , Japan , Kenya , Cambodia , Saint Kitts And Nevis , South Korea , Kuwait , Cayman Islands , Kazakhstan , Lebanon , Saint Lucia , Liechtenstein , Sri Lanka , Liberia , Lesotho , Lithuania , Luxembourg , Latvia , Morocco , Moldova , Madagascar , Macedonia , Mali , Myanmar , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mexico , Malaysia , Mozambique , Namibia , Niger , Nigeria , Nicaragua , Netherlands , Norway , Nepal , New Zealand , Oman , Panama , Peru , Papua New Guinea , Philippines , Pakistan , Poland , Puerto Rico , Portugal , Paraguay , Qatar , Reunion , Romania , Russia , Rwanda , Saudi Arabia , Sudan , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , El Salvador , Turks And Caicos Islands , Chad , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , TP , Turkey , Trinidad and Tobago , Taiwan , Tanzania , Ukraine , Uganda , United States , Uruguay , Uzbekistan , Saint Vincent And The Grenadines , Venezuela , U.S. Virgin Islands , Vietnam , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Physical

  • Maximum Height
    1.15inches ( 29mm , 2.9CM )
  • Maximum Width
    4.25inches ( 108mm , 10.8CM )
  • Maximum Depth
    2.25inches ( 57mm , 5.7CM )
  • Net Weight
    0.2lbs. ( 0.09KG )
  • Shipping weight
    1.2lbs. ( 0.55KG )
  • Shipping Height
    2.0inches ( 51mm , 5.1CM )
  • Shipping Width
    9.25inches ( 235mm , 23.5CM )
  • Shipping Depth
    6.4inches ( 163mm , 16.3CM )

Environmental

  • Operating Temperature
    32 - 113 °F ( 0 - 45 °C )
  • Operating Relative Humidity
    0 - 95 %
  • Operating Elevation
    0-10000ft ( 0-3000meters )
  • Storage Temperature
    -15 - 65 °C
  • Storage Relative Humidity
    0 - 95 %
  • Storage Elevation
    0-50000ft ( 0-15000meters )

Conformance

  • Standard warranty
    2 years repair or replace

Sustainable Offer Status

  • RoHS
    Compliant
  • REACH
    REACH: Contains No SVHCs

General

  • Type of External Sensors Supported
    Door Contact, Temperature
  • Maximum Number of Connected Devices
    3.0
  • Number of Additional Camera Pods
    3.0
  • Number of Additional Sensor Pods
    3.0
  • Sensor Humidity Range
    10% to 90% non-condensing +/– 5% RH %
  • Sensor Temperature Range
    1.6°C to 48.8°C (35°F to 120°F) +/- 1°C °F
Manuals and Warranties
Title
Size
Updated On
PDF

Size

462KB

Updated On

2017-08-10

Installation instructions and configuration information for the NBPD0180 - Netbotz Wireless Sensor Pod
PDF

Size

1317KB

Updated On

2017-08-03

Provides complete details on how to use the Web Client and Advanced View software interfaces for your security and environmental management system when using a NetBotz Rack Monitor 550, NetBotz Rack Monitor 450, NetBotz Room Monitor 355, or NetBotz Room Monitor 455.
Agency Approvals
Title
Size
Updated On
PDF

Size

362KB

Updated On

2017-11-02

CCC Exemption
PDF

Size

142KB

Updated On

2017-02-18

EU regulatory requirement
PDF

Size

1039KB

Updated On

2017-02-18

Regulatory Compliance Globtek OEM
PDF

Size

986KB

Updated On

2017-02-16

Regulatory Compliance
PDF

Size

113KB

Updated On

2017-02-16

Sales in the EU
PDF

Size

21KB

Updated On

2017-02-16

Regulatory Compliance
PDF

Size

23KB

Updated On

2017-02-16

Regulatory Compliance
Title
Size
Updated On

Category

Sub-Category


Rack PDU, Basic, 0U/1U, 208V, 60A, (3) C19

Reliable rack power distribution

AP6039A
$469.00
Horizontal Cable Manager, 3U x 6" Deep, Single-Sided with Cover

High density 3U, 6-in (150-mm) deep, horizontal cable manager with cover. Features cable access slots with pre-installed brush strips in the backplate for front to back cable pass-through.

AR8605
$129.99
Horizontal Cable Manager, 2U x 6" Deep, Single-Sided with Cover

High density 2U, 6-in (150-mm) deep, horizontal cable manager with cover. Features cable tie-off and cable access slots in the backplate for front to back cable pass-through.

AR8606
$89.99
1U 19" Black Modular Toolless Airflow Management Blanking Panel - Qty 10

Modular toolless 1U Airflow Management Blanking Panel to prevent air recirculation by occupying unused rack space (Qty. 10).

AR8136BLK
$49.99
APC Service Bypass Panel- 200/208/240V; 100A; MBB; Hardwire input; (6) L14-30R output

Extremely reliable service bypass panels designed for APC InfraStruXure® Type A, Smart-UPS, and Symmetra UPS products.

SBP16KRMP4U
$1,150.00
Call for Availability
800-800-4272
Call for Availability  800-800-4272
Rack PDU, Metered, 1U, 15A, 100/120V, (8) 5-15

Metered rack Power Distribution Units (PDUs) provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur.

AP7800B
$419.00
Sliding Shelf 100lbs/45.5kg Black

Sliding shelf to enable the mounting of tower units, monitors, and other equipment into the rack environment.

AR8123BLK
$219.99
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15

Switched Rack Power Distribution Units (PDUs) provide advanced load monitoring combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management.

AP7900B
$579.00
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A, 208V, (21) C13 & (3) C19

APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.

AP8659NA3
$1,275.00
NetBotz Wireless Temperature & Humidity Sensor

Wireless sensor that monitors temperature and humidity in the Data Center or Distributed Network Closet

NBWS100H
$149.99
Call for Availability
800-800-4272
Call for Availability  800-800-4272

Show results per page