InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz

Share:

InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz

ACSC100

Description: Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers

Includes : Exhaust Duct Kit , Installation Guide , Operations and Maintenance Manual

InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz

Call for Availability
800-800-4272
Includes: Exhaust Duct Kit , Installation Guide , Operations and Maintenance Manual

ACSC100 Features

InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz

  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Automatic restart
    Returns the unit to its last operating status in the event of a power failure.
  • Dry contact output
    Provides remote notification of failures when used with APC environmental monitoring unit or system.
  • Easy to install
    Innovative design allows for fast, easy installation by almost anybody.
  • Fault-tolerant fan system
    In the event of a fan failure, the remaining fan(s) will continue to operate.
  • Field replaceable components
    Fans and electronics module can be readily replaced without uninstalling the unit.
  • Horizontal airflow pattern
    Removes heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.

InRow Direct Expansion Features & Benefits

  • Modular design
    Modular design provides scalable solutions to add cooling as demand increases.
  • Scaleable densities
    Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Rack inlet temperature control
    Reduces the risk of hot spots at the rack level
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.
  • In-Row architecture
    Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
  • Building management system integration
    Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Microprocessor controller
    Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
  • Real-Time capacity monitoring
    Real-time display of current and available cooling.
Product Distribution
Product Distribution

Antigua and Barbuda , Anguilla , Netherlands Antilles , Aruba , Barbados , Bermuda , Brazil , Belize , Canada , Colombia , Costa Rica , Cuba , Dominican Republic , Ecuador , Falkland Islands , Guatemala , Guyana , Honduras , Jamaica , Cayman Islands , Mexico , Nicaragua , Panama , Peru , Puerto Rico , El Salvador , Trinidad and Tobago , United States , Venezuela , U.S. Virgin Islands

Print Technical Specification

Input

  • Input frequency
    60 Hz
  • Input Connections
    NEMA L6-20P
  • Number of Power Cords
    1
  • Input Power
    2940.0Watts

Communications & Management

  • Control panel
    Multi-function LCD status and control console

Physical

  • Maximum Height
    78.4inches ( 1991mm , 199.1CM )
  • Maximum Width
    11.8inches ( 300mm , 30.0CM )
  • Maximum Depth
    42.1inches ( 1069mm , 106.9CM )
  • Rack Height
    42U
  • Net Weight
    365.0lbs. ( 165.92KG )
  • Shipping weight
    475.2lbs. ( 216.0KG )
  • Shipping Height
    84.9inches ( 2156mm , 215.6CM )
  • Shipping Width
    30.0inches ( 762mm , 76.2CM )
  • Shipping Depth
    44.8inches ( 1138mm , 113.8CM )
  • Color
    Black

Environmental

  • Storage Temperature
    0 - 40 °C
  • Storage Relative Humidity
    0 - 95 %
  • Storage Elevation
    0-15000ft ( 0-4500meters )
  • Audible noise at 1 meter from surface of unit
    80.0dBA

Conformance

  • Approvals
    BSMI, EN 55022 Class A, FCC Part 15 Class A, ICES-003, UL Listed, VCCI, VDE
  • Standard warranty
    1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up

General

  • Air Discharge Patterns
    Horizontal
  • Air Flow
    1200.0CFM ( 566.34lps )
  • Amp Draw In-Rush
    56.0A
  • Compressor Type
    Rotary
  • Condensate Pump Capacity
    1.3gal/hour ( 0.002lps )
  • Intake Air
    Rear Return
  • Refrigerant Charge
    3.0pounds ( 1.36pounds )
Manuals and Warranties
Title
Size
Updated On
PDF

Size

99KB

Updated On

2018-06-19

Modbus Register Map
PDF

Size

513KB

Updated On

2018-06-14

PDF

Size

1057KB

Updated On

2018-06-13

Receiving, Unpacking and Moving Guide for 300mm, 600mm, and 750mm Rack Based Cooling Products
PDF

Size

2523KB

Updated On

2018-06-12

Product Overview; Safety; Site Preparation; Installation; Electrical Connection; Start-up; General Specifications; Technical Specifications; Troubleshooting; Warranty and Service
PDF

Size

649KB

Updated On

2018-06-12

General Specifications; Technical Specifications; Bid Specifications
PDF

Size

27KB

Updated On

2018-06-12

Release Notes for v3.7.4
PDF

Size

309KB

Updated On

2018-06-12

Sheet explaining the new voltage and how to remove the jumper from the new universal voltage condensate pump.
PDF

Size

691KB

Updated On

2018-06-12

Safety
Brochure
Title
Size
Updated On
PDF

Size

456KB

Updated On

2018-06-15

Brochure outlining APC's row-based direct expansion product family including the InRow SC and InRow RD products. This brochure contains detailed product overview as well as sku specific information technical data
Agency Approvals
Title
Size
Updated On
PDF

Size

1082KB

Updated On

2018-06-14

CCC out of scope letter from UL China
PDF

Size

27KB

Updated On

2016-11-26

United States Safety Approval for the 5 kW InRow Self Contained Air Conditioner
Stencils
Title
Size
Updated On
PDF

Size

360KB

Updated On

2016-12-16

Cooling Solutions
Source

Size

360KB

Updated On

2016-12-16

Cooling Solutions
Bid Spec
Title
Size
Updated On
PDF

Size

17KB

Updated On

2018-06-18

CSI formatted guide specifications for the InRow SC unit
Source ZIP

Size

66KB

Updated On

2018-06-18

CSI formatted guide specifications for the InRow SC unit
Title
Size
Updated On
Cooling Solutions, Row Cooling Accessories
CAD Source File
3156KB
2016-12-08

Cooling Solutions, InRow Direct Expansion, Package
BIM Models, Cooling Solutions, InRow SC

Firmware Upgrades

Firmware Upgrades
Part Number
Updated On

Firmware Upgrades

PowerNet MIB v4.2.6

Part Number

SFPMIB426

Updated On

2018-01-24

Firmware Upgrades

InRow SC Firmware Update V374

Part Number

SFSCFW374

Updated On

2015-06-18
Wizards and Configurators
Part Number
Updated On

Part Number

SFDIPW503

Updated On

2018-04-12

Category

Sub-Category


Advanced Operator Training for In-Row Cooling

Get the most from your Schneider Electric solution while learning from our industry proven professionals. Increase your knowledge and confidence operating your data center and managing your facility's physical infrastructure.

Upgrade to provide Monthly 7X24 Preventive Maintenance Visits

Performed at any point for your UPS or cooling system lifecycle, regardless of your service contract status. On-demand services include part replacement services for batteries, parts, reactive time and materials (T&M), etc.

7X24 Scheduling Upgrade from Existing Preventive Maintenance Service

Performed at any point for your UPS or cooling system lifecycle, regardless of your service contract status. On-demand services include part replacement services for batteries, parts, reactive time and materials (T&M), etc.


Show results per page

Related Products, Accessories & Services

View all accessories and replacement batteries for this product