Uniflair LE

Perimeter cooling for medium and large data center environments

Explore Uniflair in 3D animation.
Leading edge precision cooling solutions specifically designed to maintain temperature and humidity within extremely tight tolerances. Perfect for racked and non-racked IT loads, these products meet the diverse requirements of any data center environment. These intelligent units monitor the status of components and environmental parameter to ensure correct functionality during all modes of operation. When combined with hot or cold aisle containment solutions, the Uniflair LE products can further improve efficiency and achieve higher densities.

Read More
Products Part Number Price
Product High Efficiency Chilled Water Units, Downflow, Backward Curved Fans and Electronic Commutated Motor Part Number HDCV Price -- Call for Availability
1890 272877 1890 272877
Product Direct expansion air-cooled unit downflow with EC backward curved fans and brushless VSD compressors Part Number IDAV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Energy Saving precision air conditioner, Downflow with EC Fans and VSD compressors Part Number IDEV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion water cooled precision air conditioner, Downflow with EC fans and VSD compressors Part Number IDWV Price -- Call for Availability
1890 272877 1890 272877
Product Direct expansion air cooled precision air conditioner, Upflow with EC fans and VSD compressors Part Number IUAV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Energy Saving precision air conditioners, Upflow with EC fans and VSD compressors Part Number IUEV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion water cooled precision air conditioners, Upflow with EC fans and VSD compressors Part Number IUWV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion air cooled precision air conditioners, Underfloor EC fans and VSD compressors Part Number IXAV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Energy Saving precision air conditioners, Underfloor EC fans and VSD compressors Part Number IXEV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion water cooled precision air conditioner, Underfloor EC fans and VSD compressors Part Number IXWV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion air cooled precision air conditioner, Downflow with EC fans Part Number LDAV Price -- Call for Availability
1890 272877 1890 272877
Product Chilled water precision air conditioner, downflow with EC fans Part Number LDCV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Energy Saving precision air conditioners, Downflow with EC fans Part Number LDEV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion water cooled precision air conditioner, Downflow with EC fans Part Number LDWV Price -- Call for Availability
1890 272877 1890 272877
Product Chilled Water precision air conditioner, upflow with EC fans Part Number LUCV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Air-Cooled Units, Downflow with Backward Curved Fans Part Number TDAR Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Air-Cooled Unit, Downflow with Backward Curved Fans and Electronic Commutated Motor Part Number TDAV Price -- Call for Availability
1890 272877 1890 272877
Product Twin Cool Water-Cooled Units, Downflow with Backward Curved Fans Part Number TDDR Price -- Call for Availability
1890 272877 1890 272877
Product Twin Cool Water-Cooled Units, Downflow with Backward Curved fans and Electronic Commutated Motor Part Number TDDV Price -- Call for Availability
1890 272877 1890 272877
Product Energy Saving Units, Downflow with Backward Curved Fans Part Number TDER Price -- Call for Availability
1890 272877 1890 272877
Product Energy Saving Units, Downflow with Backward Curved Fans and Electronic Commutated Motor Part Number TDEV Price -- Call for Availability
1890 272877 1890 272877
Product Twin Cool Air-Cooled Units, Downflow with Backward Curved Fans Part Number TDTR Price -- Call for Availability
1890 272877 1890 272877
Product Twin Cool Air-Cooled Units, Downflow with Backward Curved Fans and Electronic Commutated Motor Part Number TDTV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Water-Cooled Units, Downflow with Backward Curved Fans Part Number TDWR Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Water-Cooled Unit, Downflow, Backward Curved Fans and Electronic Commutated Motor Part Number TDWV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Air-Cooled Units, Upflow with Backward Curved Fans Part Number TUAR Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Air-Cooled Unit, Upflow with Backward Curved Fans and Electronic Commutated Motor Part Number TUAV Price -- Call for Availability
1890 272877 1890 272877
Product Twin Cool Water-Cooled Units, Upflow with Backward Curved Fans Part Number TUDR Price -- Call for Availability
1890 272877 1890 272877
Product Twin Cool Water-Cooled Units, Upflow with Backward Curved Fans and Electronic Commutated Motor Part Number TUDV Price -- Call for Availability
1890 272877 1890 272877
Product Energy Saving Units, Upflow with Backward Curved Fans Part Number TUER Price -- Call for Availability
1890 272877 1890 272877
Product Energy Saving Units, Upflow with Backward Curved Fans and Electronic Commutated Motor Part Number TUEV Price -- Call for Availability
1890 272877 1890 272877
Product Twin Cool Air-Cooled Units, Upflow with Backward Curved Fans Part Number TUTR Price -- Call for Availability
1890 272877 1890 272877
Product Twin Cool Air-Cooled Units, Upflow with Backward Curved Fans and Electronic Commutated Motor Part Number TUTV Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Water-Cooled Units, Upflow with Backward Curved Fans Part Number TUWR Price -- Call for Availability
1890 272877 1890 272877
Product Direct Expansion Water-Cooled Units, Upflow, Backward Curved Fans and Electronic Commutated Motor Part Number TUWV Price -- Call for Availability
1890 272877 1890 272877
Total Cost of Ownership
Optimized management Connection between the Computer Room Air Conditioners and the chillers guarantees energy efficiency, based on real instantaneous load conditions (optional)
Electronically Commutated Fans Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
Modular strategy Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expeditures and provides deferred investment throughout the life of the facility.
Economization Achieved by utilizing cool ambient air during winter months to take advantage of economizer hours and eliminating compressor operation.
Tandem compressors Quiet and efficient operation of compressors, connected on a common refrigerant circuit for staged capacity control (not available for some models/configuration)
Energy Management
Building Management Systems Units are designed to work with the most common BMS systems including BACnet and Modbus.
Network interface Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
Local area network Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations
Automatic Floor Pressurization System Ensures stable airflow pressurization under floor regardless of changes made above the floor
Availability
Redundant Components Single points of failure in the system have redundant compononents to maintain availability and reliability.
Electronic expansion valve Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring
Direct drive motors Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
Active response control Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
Multi-functional Microprocessor Controller Allows the units to restart after a power failure without intervention; Allows for room level redundancy with up to ten units operating in a group; User friendly navigation with icon based displays to indicate mode of operation as well as room conditions; Allows for communication with multiple Building Management System protocols.
Serviceability
Easy service access Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Service monitoring All the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.
Operational Service Allows critical components to be maintained/replaced while the system is in operation.

Product 1

Select a family or part number to compare

Select Family
Select Part Number

Product 2

Select a family or part number to compare

Product 3

Select a family or part number to compare