BP280S
DISCONTINUED : recommended replacement product BR500

Back-UPS Pro 280VA

BP280SBP280S
More Images

APC Back-UPS Pro, 180 Watts / 280 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232

Includes: CD with software, Cord management straps, Smart UPS signalling RS-232 cable, User Manual

Output

Output Power Capacity
180 Watts / 280 VA
Max Configurable Power
180 Watts / 280 VA
Nominal Output Voltage
120V
Output Connections
(1) NEMA 5-15R (Surge Protection)
(2) NEMA 5-15R (Battery Backup)

Input

Nominal Input Voltage
120V
Input Frequency
50/60 Hz +/- 3 Hz (auto sensing)
Input Connections
NEMA 5-15P
Cord Length
6 feet (1.83 meters)
Input voltage range for main operations
82 - 147V
Input voltage adjustable range for mains operation
78 - 152V

Batteries & Runtime

Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time
7 hour(s)
Replacement Battery
RBC™ Quantity
1

Communications & Management

Interface Port(s)
DB-9 RS-232
Control panel
LED status display with On Line : On Battery : Replace Battery and Overload indicators
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering

Surge energy rating
480 Joules
Filtering
Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449
Data Line Protection
RJ-45 Modem/Fax/DSL/10-100 Base-T protection

Physical

Maximum Height
5.90 inches (150 mm)
Maximum Width
3.40 inches (86 mm)
Maximum Depth
13.30 inches (338 mm)
Net Weight
16.60 lbs. (7.55 kg)
Shipping Weight
20.40 lbs. (9.27 kg)
Shipping Height
10.60 inches (269 mm)
Shipping Width
7.80 inches (198 mm)
Shipping Depth
18.40 inches (467 mm)
Color
Beige

Environmental

Operating Environment
32 - 104 °F (0 - 40 °C)
Operating Relative Humidity
0 - 95%
Operating Elevation
0-10000 feet (0-3000 meters)
Storage Temperature
5 - 113 °F (-15 - 45 °C)
Storage Relative Humidity
0 - 95%
Storage Elevation
0-50000 feet (0-15000 meters)
Audible noise at 1 meter from surface of unit
45.00 dBA

Conformance

Regulatory Approvals
CSA,FCC Part 15 Class B,FCC Part 68,UL 1778
Standard Warranty
2 years repair or replace
Equipment protection policy
Lifetime : $75000